SAFETY PRECAUTIONS 

  DANGER 

  ATTENTION 

 

Wiring work must be performed by electrical engineers, otherwise 
there is danger of electric shock or damage to the system. 

 

Before wiring, make sure that the power is off, otherwise there is 
danger of electric shock or fire. 

 

The installed cable must meet the requirements, and the power 
distribution part must comply with the safety regulations. 

 

Installation must be carried out in strict accordance with the 
following installation steps, otherwise it will cause product damage. 

 

During normal operation, it is strictly forbidden to directly touch the 
terminals such as output and input to avoid electric shock hazard. 

 

Do not open the casing of the machine directly during normal 
operation, otherwise it may cause electric shock. 

 

When removing the outer casing, be sure to disconnect the input 
and output circuits, otherwise there is danger of electric shock. 

 

Even if the casing is disassembled, there is still residual power 
inside the machine. Do not touch the bare part of the line directly to 
avoid electric shock. 

 

Maintenance and overhaul must be performed by professional 
maintenance personnel. Users should not disassemble the machine 
to avoid electric shock and product damage 

 

During the carry process, avoid strong vibration, falling, bumping, 
and prohibit the box from being inverted. Do not lose the 
accessories and user manual, warranty card, etc. when unpacking. 

 

It is forbidden to modify the system by itself to avoid serious 
accidents. 

 

When an abnormality occurs inside the machine, immediately 
disconnect the power supply and load. 

 

If the product is found to be damaged or missing 
parts, it cannot be installed, otherwise it may 
malfunction. If the packing list does not match 
the physical name, please do not install and 
contact the dealer in time. 

 

When handling and installing, please lift it gently 
to avoid injury to the foot or damage to the 
product. 

 

Keep the system away from flammable objects 
and away from heat sources. 

 

Do not drop debris into the system when 
installing this system, otherwise it may cause 
system failure. 

 

Before running, please ensure that the product 
is used within the allowable working range, 
otherwise it will cause damage to the product. 

 

When the product is not used for a long time, 
the battery should be discharged to between 
45% and 60% of the battery, and the battery 
output should be disconnected to avoid the 
battery being emptied. 

 

Be careful when handling, so as not to hurt your 
body. 

 

 

Содержание B09ULF

Страница 1: ...INSTALLATION MANUAL B09ULF LITHIUM BATTERY...

Страница 2: ...attery Modules 7 5 Product Installation 9 5 1 Device list 9 5 2 Before installation 11 5 3 System installation 12 6 Electrical Connection 17 6 1 System Wiring 17 6 2 DIP switch settings 20 6 3 Groundi...

Страница 3: ...ation of the system The system allows flexibility in configuration which can be widely applied to household energy storage scenarios Architecture of the battery system is shown on the diagram here One...

Страница 4: ...Maintenance and overhaul must be performed by professional maintenance personnel Users should not disassemble the machine to avoid electric shock and product damage During the carry process avoid str...

Страница 5: ...ponsible for any injury or loss caused by illegal operation Symbol Definition Symbol Definition Note Due to the danger of not operating as required it may result in moderate or minor injury to the per...

Страница 6: ...months The SOC before storage is kept in the range of 40 to 60 20 45 C 3 months 20 50 C 1 month 12 environment humidity No condensation 13 Altitude 14 System noise 40dB 16 Protection level IP55 17 Pol...

Страница 7: ...rface 11 button Battery box start stop button 12 Status Display Power and operation fault display 13 14 Input and output positive Battery box power output positive interface 15 Grounding hole Used to...

Страница 8: ...sistor is inserted in the first and last CAN communication interfaces for parallel CAN communication matching resistors The terminators are attached as an accessory at the time of shipment DIP switch...

Страница 9: ...e installation please check whether the equipment is in good condition and check whether the parts of the accessory package are consistent with the list No Picture Name Specification Model Q ty Remark...

Страница 10: ...ower line UL10269 3AWG 600V Orange 2650mm Label 5619100023611 1 pcs Used to connect the battery module negative terminal to the inverter battery side negative electrode 15 Cable with connector 24AWG C...

Страница 11: ...product is prohibited from tilting or side discharging and the ventilation on both sides is good leaving a heat dissipation bearing requirements of the battery system Installation location should avo...

Страница 12: ...nstallation bracket is used as the standard The left and right sides of the cabinet should be left and installed 300mm cooling space 5 3 2 Installation steps Move the battery cabinet to the installati...

Страница 13: ...binet can see the handle as shown in push the handle up the front door pops open rotate the front door 90 degrees to the left push the front door up as shown in The front door latch is disengaged as s...

Страница 14: ...g of 406 4mm 16 inches or 304 8mm depending on the width of the mounting wall 12 inch spacing hole draw a mark at the mounting hole with a pen drill the hole expansion screw seat into the hole and kno...

Страница 15: ...as shown in below and press the battery box baffle firmly using the screws removed in step 5 The side mounted battery module is shown as Step 9 On the front of the cabinet as shown in fix the four ba...

Страница 16: ...rst the second battery box note the placement of B and B as shown above Step 11 Before closing the cabinet please refer to Section 6 for DIP switch settings System wiring Matching resistor installatio...

Страница 17: ...d to ensure that the battery module is in the off state all external connection cables are routed from the top of the cabinet through the hole 6 1 1 Connector description The battery B and B terminals...

Страница 18: ...6 Use the cable labeled 5619100023601 to pull the B terminal from BAT3 through the waterproof connector to the negative battery terminal of the inverter or charger Step 7 Use the 150mm COM cable label...

Страница 19: ...al of the DC Bus Step 2 Use the cable labeled 5619100023601 to connect the B terminals of BAT3 of Cabinet 1 to a negatitive terminal of a DC Bus Use another cable labeled 5619100023601 to connect the...

Страница 20: ...itch settings Address 0 1 2 3 4 5 6 7 DIP switch positions Slave MASTER SLAVE 1 SLAVE2 SLAVE3 SLAVE4 SLAVE5 SLAVE6 SLAVE7 SLAVE8 Cabinet 1 Cabinet 2 MASTER Address 0 ADDR 0000 SLAVE4 Address 3 ADDR 01...

Страница 21: ...battery module to the casing panel Fix one end of the yellow green grounding wire labeled BAT GND to the grounding point of the chassis panel with the screw and connect the other end to the grounding...

Страница 22: ...ghts to indicate protection operation power and function Legend light stays on light flashing at 1 Hz Mode Status Capacity LED Low to high ALM RUN Shutdown Charging SOC 0 25 SOC 26 50 SOC 51 75 SOC 76...

Страница 23: ...re connected in parallel insert the RS485 communication interface into the RS485 interface on the front panel of the MASTER address 0000 battery box communicate with the computer through the 485 commu...

Страница 24: ...Y R e v 1 2 0 1 9 D a r f o n E l e c t r o n i c s C o r p P a g e 2 4 o f 2 8 Parallel summary of module information Enter the battery pack information 4 click the current state you can see the par...

Страница 25: ...I N S T A L L A T I O N M A N U A L B 0 9 U L F L I T H I U M B A T T E R Y R e v 1 2 0 1 9 D a r f o n E l e c t r o n i c s C o r p P a g e 2 5 o f 2 8 Parallel summary information...

Страница 26: ...situation Short battery discharge time Low battery Keep the product charged for more than 4 hours to fully charge the battery Product overload Check load status and remove non critical products Batte...

Страница 27: ...ws and regulations The system is heavy and must be transported by mechanical means The equipment and packaging cannot be drenched so it cannot be transported in the open air 9 3 System storage Storage...

Страница 28: ...an Taoyuan 333 Taiwan R O C Tel 886 3 2508800 USA Office Darfon America Corp 103A Pioneer Way Mountain View CA 94041 Tel 1 650 316 6300 For more information www darfonsolar com 2018 Darfon Electronics...

Отзывы: