background image

 

NET-FRM01 Users Manual (Rev 1.3) 

 

 

                                                                  -

29-                                                     

http://www.daqsystem.com

 

(3) “

Get Serial” button   

Get the data from UART buffer. 

 

(4) 

”Auto Get Signal” toggle

 

When check this box, the serial data from Frame Grabber will be displayed in the below   

box.   

 

(5) 

“Clear Data” button 

Clear the UART Receiver buffer. 

 

(6) 

“CC Out” button

 

              Write CC(Camera Control) Data. 

 

(7) 

“CC Read” button

 

              Read CC(Camera Control) Data. 

 

 

 

Содержание NET-FRM01

Страница 1: ...system is believed to be accurate and reliable However no responsibility is assumed by DAQ system for its use nor for any infringements of patents or other rights of third parties which may result fro...

Страница 2: ...ayout 3 2 Functional Blocks 3 3 Connector Pin out 3 3 1 REF1 RJ45 Connector 3 3 2 J1 MDR26 Connector 3 3 3 J3 Connecter 3Pin Header 2 54mm 3 3 4 JP1 Connector 3 3 1 SW1 Switch 4 Driver Network IP Setu...

Страница 3: ...ally PC DAQ system provides a sample program to use the board briefly so you can test the API pr ovided insource form so the user can be used to modify Please refer to Chapter 5 for a deta iled descri...

Страница 4: ...45 Ethernet Connector Selectable Board Network Information IP etc Supports Fixed IP UART Data 8 bits 1bit start 1 stop No parity 9600 19200 38400 57600 115200bps Rx Tx O S Windows XP SP1over Windows...

Страница 5: ...g the frame data and are transmitting receiving the UART data NET FRM01 10 100 1000Mbps Ethernet Tranceiver FPGA Core Logic DDR2 1 DDR2 2 M D R I 26 Clock Rx Tx RX0 RX1 Camera Link Receiver RX2 Camera...

Страница 6: ...tage transmission to refer only to the data transfer on the ground however Single ended system is impossible Camera Link has multiple configuration with depending on the amount of data to be transferr...

Страница 7: ...NET FRM01 Users Manual Rev 1 3 7 http www daqsystem com the Receiver part of Frame Grabber Figure 2 2 Base Camera Link Block Diagram...

Страница 8: ...m of Figure 2 4 Camera Link cable is typically used 26 Pin Mini MDR Connecter is located at the end of the cable as like Figure 2 5 Figure 2 6 is 26 Pin Mini MDR Connecter placed at the Camera or Fram...

Страница 9: ...cate with the camera LVDS lines is transmitted through one MDR cable In order to use the MDR Medium Full Configuration is used other cable and has a total 64bit wide video path The transmitted signal...

Страница 10: ...D0 CC2 CC2 CC_D1 CC3 CC3 CC_D2 CC4 CC4 CC_D3 Figure 2 6 Camera Control LVDS Digital Output Circuit The serial input signal through the Camera link cable is used for general input circuit from NET FRM0...

Страница 11: ...AQ system U5 U9 J2 U7 J1 U2 SW1 SW2 REF6 J4 D2 D3 D5 D4 D6 U1 U6 U4 U8 U3 REF1 REF2 123 789 123 789 A C E G J L N R A C E G J L N R www daqsystem com REF4 J3 J5 REF5 D1 Y1 JP1 Figure 3 1 NET FRM01 Lay...

Страница 12: ...000Mbps Ethernet Transceiver provides a 25MHz clock 50MHz is supplied to the FPGA 4 Ethernet Module REF5 10 100 1000Mbps Ethernet Module RJ 45 Connector 5 10 100 1000Mbps Ethernet Transceiver REF6 The...

Страница 13: ...h RJ 45 connector REF1 for Network connection and J1 connector for external Image Frame connection Camera Link Signals 3 3 1 REF1 RJ 45 Connector When viewed from the front of the cable is connected t...

Страница 14: ...era link standard so please refer to the Camera link standard document for more description and information 3 10 9 8 7 6 1 2 5 4 19 18 17 16 15 14 13 12 11 24 23 22 21 20 Inner shield Inner shield 26...

Страница 15: ...ck 10 X2 Camera link LVDS receive data2 11 X1 Camera link LVDS receive data1 12 X0 Camera link LVDS receive data0 13 Inner Shield 14 Inner Shield 15 CC4 Camera Control output 4 16 CC3 Camera Control o...

Страница 16: ...J3 Connector Top View Table 3 J3 PIN OUT Description No Name Description 1 U_SPI_MISO Tx Transceiver Data 2 U_SPI_MOSI Rx Receiver Data 3 GND Ground 3 3 4 JP1 Connector It is an external 12V DC Jack P...

Страница 17: ...g IP Internet Protocol address identifier It is possible to install and use the service on the network Filter Driver 4 1 Filter Driver Installation for Win XP Installed a filter driver can reduce the...

Страница 18: ...NET FRM01 Users Manual Rev 1 3 18 http www daqsystem com In the Internet Protocol TCP IP window the install is selected and then selects a service Figure 4 2 Network Component Type Selection...

Страница 19: ...NET FRM01 Users Manual Rev 1 3 19 http www daqsystem com Select a Have Disk in the Select Network Service and click Browse B You can find a netsf ini file from the provided CD ROM and then click OK...

Страница 20: ...NET FRM01 Users Manual Rev 1 3 20 http www daqsystem com Select Network Service and then click the OK and requires a check of compatibility...

Страница 21: ...NET FRM01 Users Manual Rev 1 3 21 http www daqsystem com When the driver installation is complete you can see DAQ System Filter Driver as shown below...

Страница 22: ...not share a computer and can use a computer in the office please ask them to contact the administrator user of your PC you are given administrator rights to your user account The rest of the process i...

Страница 23: ...dress in the Internet Protocol TCP IP as shown Figure 4 1 The NET FRM01 board 192 168 33 129 IP is used as the fixed identifier This identifier does not overlap with the appropriate choice of IP 255 2...

Страница 24: ...www daqsystem com When you use the NET FRM01 it is possible not to install the filter driver as section 4 1 However using the filter driver can be reduced the PC s resources Figure 4 5 PC CPU Usage w...

Страница 25: ...NET FRM01 Users Manual Rev 1 3 25 http www daqsystem com Figure 4 6 PC CPU Usage When install the filter driver...

Страница 26: ...ser be familiar with the board operation and to make the program development easier You can find the sample program in the CDROM accompanying with the board Before using the program as part of Network...

Страница 27: ...e Selection It selects a Video Data Mode of 8bit 16bit 24bit 32bit 4 Get Res button It shows the image resolution 5 Start button It starts the image transfer It is a Toggle button press again stop the...

Страница 28: ...Delay 0 15 after transfer Package The unit is 5us 13 Shift Bits It is an option for Black White Camera test the bits 0 8 of the input frames can be moved to the right For example you can view the imag...

Страница 29: ...the data from UART buffer 4 Auto Get Signal toggle When check this box the serial data from Frame Grabber will be displayed in the below box 5 Clear Data button Clear the UART Receiver buffer 6 CC Out...

Страница 30: ...8bit Data 1 Stop bit No parity Baud Rates 9600 19200 38400 57600 115200 Power Requirement Voltage 12V Max 1A Environment Caution When using internal Operating Temperature 0 60 Storage Temperature 20 7...

Страница 31: ...NET FRM01 Users Manual Rev 1 3 31 http www daqsystem com A 2 Physical Dimension Dimensions of the board are as follows Top View 4 5 4 5 13 1 6 5 0 20 Right Side View 110 79 5 32 3 0 29 21 6 5 47...

Страница 32: ...NET FRM01 Users Manual Rev 1 3 32 http www daqsystem com References 1 AN201 How to build application using API DAQ system 2 AN342 NET FRM01 API ver1 0 DAQ system...