background image

 

  

 

 

   

 

Ordercode: D3901 

Odin S-18A Line Array Sub 

Warning 

 

 

 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 
 

Your shipment includes: 

 

Odin S-18A Line Array Sub 

 

Power cable NOT included 

 

Network cable NOT included 

 

User manual 

 

 

 

 

Safety Instructions 

Every person involved with the installation, operation and maintenance of this system has to: 

 

be qualified 

 

follow the instructions of this manual 

 

 

 
Before you initial start-up, please make sure that there is no damage caused by transportation.  
Should there be any, consult your dealer and do not use the system. 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
Please consider that damages caused by manual modifications to the system are not subject to 
warranty. 
This system contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT! 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the system. 
 

 

Always disconnect power from the mains, when system is not used. Only handle the power cord by 
the plug. Never pull out the plug by tugging the power cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

Содержание D3901

Страница 1: ...Odin S 18A Line Array Sub V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3901 MANUAL ENGLISH ...

Страница 2: ...onnection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 7 Connection Example 7 Set Up and Operation 8 Preset Selector 8 Presets 8 Connection Cables 8 How to Make a Data Cable 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 ...

Страница 3: ...ake sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused by manual modifications to the system are not subject to warrant...

Страница 4: ...um could be created Make sure that there is sufficient room on all sides of the system for air circulation Make sure you do not use the wrong kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with partic...

Страница 5: ...estion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visi...

Страница 6: ... 136dB Cooling passive cooling forced cooling inside Audio connector 3 pin XLR connector IN OUT Data connector RJ45 Data IN LINK cascading connector External control 9 fixed presets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic Protections Thermal Convection Fan Overload Digital Limiter Compressor Mains connec...

Страница 7: ...5 data output connector for cascading connections LED indicators SIG CLIP PROT POWER ACTIVE The indicators light up to indicate the status of the input signal 10 position preset selector Turn the selector to choose one of the 10 equalizer presets See page 8 for more information PowerCON 100 240V AC power connector IN Blue Connect to an appropriate power supply Fuse T6 3AL 250V Power switch ON OFF ...

Страница 8: ...al link 02 on your first speaker to the audio signal input 03 on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the first speaker s power input 08 to the power supply 04 Using PowerCON power cords connect the first active speaker s power link 11 to the second speaker s power input 08 Repeat this step to connect the third and fourth speaker ...

Страница 9: ... 180 Inverted Preset for live use Bands Performances Phase 180 Inverted crosspoint at 105 Hz set at a level of 0 dB 4 Entertainment Preset for entertainment use DJ Playback crosspoint at 125 Hz set at a level of 0 dB 5 Entertainment Phase 180 Inverted Preset for entertainment use DJ Playback Phase 180 Inverted crosspoint at 125 Hz set at a level of 0 dB 6 Cardioid Use the in phase preset 0 on the ...

Страница 10: ...t use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit ope...

Страница 11: ...itable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protections Thermal Convection Fan Overload Digital Limiter Compressor Mains connector Neutrik PowerCON connector IN OUT Power supply 100 240V AC 50Hz 60Hz Power consumption 2000W Enclosure construction 18 mm birch plywood resistant black paint 1 5T metal grill with fo...

Страница 12: ... 2019 ODIN ...

Отзывы: