background image

 

  

 

 

   

 

Ordercode: D3901 

Odin S-18A Line Array Sub 

Set Up and Operation

 

Follow the directions below, as they pertain to your preferred operation mode. 
Before plugging the unit in, always make sure that the power supply matches the product specification 
voltage. Do not attempt to operate a 115V specification product on 230V power, or vice versa. 
 

Preset Selector 

01)

 

Turn the preset selector (07) to choose one of the 10 presets. See below for more information. 

 

Presets 

The below presets can be selected according to the preferences of the end user. Each preset consists of 
a set of properties, unique for every purpose and location. The presets differ by the EQ, Gain and Delay 
settings. 
 

PRESET 

NAME 

DESCRIPTION 

Default 

Preset for multipurpose use, set at a level of 0 dB 

Default Phase 180° 

Inverted 

Preset (Phase 180° Inverted) for multipurpose use, set at a level of 
0 dB. 

Low Sub 

Preset for live use (Bands/Performances), crosspoint at 105 Hz, set 
at a level of 0 dB. 

Low Sub Phase 180° 

Inverted 

Preset for live use (Bands/Performances) Phase 180° Inverted, 
crosspoint at 105 Hz, set at a level of 0 dB. 

Entertainment 

Preset for entertainment use (DJ/Playback), crosspoint at 125 Hz, 
set at a level of 0 dB. 

Entertainment Phase 180° 

Inverted 

Preset for entertainment use (DJ/Playback) Phase 180° Inverted, 
crosspoint at 125 Hz, set at a level of 0 dB. 

Cardioid 

Use the in-phase preset (0) on the front side and the out-of-phase 
(polarity reverse) preset (6) on the rear. 

End Fire 

Delaying front subwoofer @1,6m between front-front (@freq 53 Hz) 

EMPTY 

 

ODIN Editor 

Default settings, configurable with the ODIN Editor. 

 
 

Connection Cables 

Take care of your cables, always holding them by the connectors and avoiding knots and twists when 
coiling them: This gives the advantage of increasing their life and reliability. 
Periodically check your cables. A great number of problems (faulty contacts, ground hum, discharges, 
etc.) are caused entirely by using unsuitable or faulty cables. 
 
For these applications the unit provides XLR and CAT-5 connectors to easily interface with 
most professional audio devices. Follow the configuration examples below for your particular 
connection. 
 

 

 
 

 

Содержание D3901

Страница 1: ...Odin S 18A Line Array Sub V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3901 MANUAL ENGLISH ...

Страница 2: ...onnection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 7 Connection Example 7 Set Up and Operation 8 Preset Selector 8 Presets 8 Connection Cables 8 How to Make a Data Cable 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 ...

Страница 3: ...ake sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused by manual modifications to the system are not subject to warrant...

Страница 4: ...um could be created Make sure that there is sufficient room on all sides of the system for air circulation Make sure you do not use the wrong kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with partic...

Страница 5: ...estion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visi...

Страница 6: ... 136dB Cooling passive cooling forced cooling inside Audio connector 3 pin XLR connector IN OUT Data connector RJ45 Data IN LINK cascading connector External control 9 fixed presets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic Protections Thermal Convection Fan Overload Digital Limiter Compressor Mains connec...

Страница 7: ...5 data output connector for cascading connections LED indicators SIG CLIP PROT POWER ACTIVE The indicators light up to indicate the status of the input signal 10 position preset selector Turn the selector to choose one of the 10 equalizer presets See page 8 for more information PowerCON 100 240V AC power connector IN Blue Connect to an appropriate power supply Fuse T6 3AL 250V Power switch ON OFF ...

Страница 8: ...al link 02 on your first speaker to the audio signal input 03 on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the first speaker s power input 08 to the power supply 04 Using PowerCON power cords connect the first active speaker s power link 11 to the second speaker s power input 08 Repeat this step to connect the third and fourth speaker ...

Страница 9: ... 180 Inverted Preset for live use Bands Performances Phase 180 Inverted crosspoint at 105 Hz set at a level of 0 dB 4 Entertainment Preset for entertainment use DJ Playback crosspoint at 125 Hz set at a level of 0 dB 5 Entertainment Phase 180 Inverted Preset for entertainment use DJ Playback Phase 180 Inverted crosspoint at 125 Hz set at a level of 0 dB 6 Cardioid Use the in phase preset 0 on the ...

Страница 10: ...t use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit ope...

Страница 11: ...itable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protections Thermal Convection Fan Overload Digital Limiter Compressor Mains connector Neutrik PowerCON connector IN OUT Power supply 100 240V AC 50Hz 60Hz Power consumption 2000W Enclosure construction 18 mm birch plywood resistant black paint 1 5T metal grill with fo...

Страница 12: ... 2019 ODIN ...

Отзывы: