Safety instructions

 

All persons admitted to operate or maintain the DanVex AD-400 dehumidifiers should read these 
instructions manual and to be briefed for its safe operation.

 

Only the personnel with sufficient knowledge of the dehumidifiers operation principle is permitted 
to perform the adsorption dehumidifiers operation and maintenance.

 

Only authorized personnel with special education is permitted to perform maintenance and repair 
works on electrical system.

 

Only authorized service center personnel is permitted to perform repair works on electrical 
components.

 

It is prohibited to install or operate the units in the locations subject to explosion hazard.

 

Before opening any panels of the unit body it is required to disconnect the dehumidifier from 
the mains.

 

Before starting any maintenance works the dehumidifier should be out-of-operation for 15 
minutes.

 

The unit's panels must be always closed except when the dehumidifier is being maintained. 

The dehumidifier can be used for air drying at atmospheric pressure only.

 

Never use the dehumidifier without filters since the drying rotor can get contaminated which will 
cause loss of efficiency.

 

This manual should always be at hand and not far from the dehumidifier.

 

The dehumidifier maintenance and inspection works should be performed in accordance with a 
fixed schedule.

 

Only original spare parts should be used.

 

It is required to receive a written approval from «DanVex Оу» or from its local representative 
for any changes or modifications of the dehumidifier.

 

Содержание AD-400

Страница 1: ...DanVex AD 400 Adsorption air dehumidi er Operation manual...

Страница 2: ...R www danvex...

Страница 3: ...NT Safety instructions 3 Introduction 4 Purpose 4 Design 4 Operation principle 5 Dimensions and weight 5 Installation 6 Technical data 7 Commissioning 7 Maintenance 8 Transportation 8 Parts list 9 War...

Страница 4: ......

Страница 5: ...explosion hazard Before opening any panels of the unit body it is required to disconnect the dehumidi er from the mains Before starting any maintenance works the dehumidi er should be out of operatio...

Страница 6: ...all volume of the rotor This material is highly ef cient for water molecules attraction and retention it is noncombustible and explosion proof with a long service life The rotor manufacturing technolo...

Страница 7: ...ondition DRY AIR and is directed to a certain part of the building or a technological process where dehumidi ed air or a certain air humidity levels are required Since the rotor rotates slowly the inc...

Страница 8: ...e rotor The rotor is reactivated by another air ow preheated to 120 C The moisture is removed from the room in the form of moist air Pic 1 Dehumidi er air ows diagram Pic 2 AD 400 dehumidi er dimensio...

Страница 9: ...upright it should be insulated and drain holes should be drilled in the lowest part of the elbow bend 2 4 mm Regeneration airduct The regeneration air duct should be as short as possible A metal net...

Страница 10: ...ls are clean and not blocked 4 Make sure that air lters are installed and clean 5 Manually turn the fans impellers and make sure they rotate freely 6 Check the internal fuse 7 Close the service panels...

Страница 11: ...per month Never use the dehumidi er without lters Rotor The rotor is maintenance free However for cleaning purposes it can be ushed out by compressed air A rotor cleaning procedure requires special k...

Страница 12: ...w danvex 1 0 Parts list Table 3 Name Number per dehumidi er Rotor drive motor 1 Condenser 1 Belt pulley 1 Rotor drive belt 1 Belt tensioner 1 Dehumidi ed air fan 1 Regeneration air fan 1 Heater 1 Roto...

Страница 13: ...ns when it supplies the Customer a repaired or a spare part Parts repair or replacement does not resultin the warranty period extension The parts and components replaced under the warranty belong to D...

Страница 14: ......

Отзывы: