0. TABLE OF CONTENTS 

 

 

1

 

1. General 
 

  1.1 

Introduction 

    3 

 

1.2 Foundation for the unit   

 

 

 

  1.3 

Minimum 

distances 

    3 

 
 

2. Transportation 
 

  2.1 

Unloading     4 

 

2.2 Lifting with a forklift 

 

 

 

 

 

2.3 Lifting with a crane 

 

 

 

 

  2.4 

Storage 

     5 

 
 

3. Installation 
 

  3.1 

Introduction 

    6 

 

 

3.1.1 Unit construction DanX – XWPS 

 

 

 

 

3.1.2 Unit construction DanX – XKS 

 

 

 

 

3.1.3 Unit construction DanX – XK  

 

 

 
 

3.2 Installation of modules    

 

 

 

 

 

3.2.1 Modules side by side   

 

 

 

 

3.2.2 Modules above each other 

 

 

10 

 

 

3.2.3 Half height hanging filter module 

 

 

10 

 

 

3.2.4 Duct mounting 

 

 

 

11 

 

 

3.2.5 Outdoor unit 

 

 

 

11 

 
 

3.3 Installation and connection of components 

 

 

12 

 

 

3.3.1 XWPS drop bridge 

 

 

 

12 

 

 

3.3.2 Condensed water outlet 

 

 

13 

   

3.3.3 

Damper 

motors 

   13 

 

 

3.3.4 Filter gauges 

 

 

 

13 

 

 

3.3.5 Flow gauges for centrifugal fans 

 

 

14 

 

 

3.3.6 Temperature sensors   

 

 

14 

 

 

3.3.7 Humidity sensor 

 

 

 

14 

 

 

3.3.8 Frequency converter for plug fans 

 

 

15 

 

 

3.3.9 Water cooled condenser 

 

 

16 

   

3.3.10 

LPHW 

coil 

   17 

 

 

3.3.11 Frost thermostat for LPHW coil 

 

 

17 

 

 

 

4. Commissioning 

 
 4.1 

Introduction     18 

 

 

4.1.1 Unit function DanX – XWPS 

 

 

18 

 

 

4.1.2 Unit function DanX – XKS 

 

 

19 

 

 

4.1.3 Unit function DanX – XK  

 

 

19 

 
 4.2 

Centrifugal 

fan 

    20 

 

 

4.2.1 Air volume measuring and setting 

 

 

20 

 
 
 
 
 
 

Содержание DanX 2/4 XKS

Страница 1: ...ponsibility for possible errors and changes Irrt mer und nderungen vorbehalten Dantherm n assume aucune responsabilit pour erreurs et modifications ventuelles DanX for swimming pools Transport install...

Страница 2: ......

Страница 3: ...ght hanging filter module 10 3 2 4 Duct mounting 11 3 2 5 Outdoor unit 11 3 3 Installation and connection of components 12 3 3 1 XWPS drop bridge 12 3 3 2 Condensed water outlet 13 3 3 3 Damper motors...

Страница 4: ...xing box XKS 28 4 5 2 Dampers XK 29 4 6 Frost thermostat 29 4 7 Filter pressure transmitter 29 5 Maintenance 5 1 Introduction 30 5 2 Maintenance plan 30 5 3 Cabinet 30 5 4 Fans 31 5 4 1 Centrifugal fa...

Страница 5: ...stable and vibration free The supporting structure must be able to bear the weight of the unit The deflection of the substructure should be max 1 mm m For the connection of the condensate drain it is...

Страница 6: ...in a safe and dry location until the installation is carried out 2 2 Lifting with a forklift If a fork lift is being used it must be ensured that the forks are long enough to reach all through under...

Страница 7: ...min 1 in the holes of the base frame and secure them Use four soft straps push them over the iron bars and put them together in the crane hook 2 4 Storage If the unit is not installed at once but sho...

Страница 8: ...nly be carried out by trained specialists or by people supervised by authorized staff It is the responsibility of the fitter to read and understand this guide and other given information 3 1 1 Unit co...

Страница 9: ...th centrifugal fans instead of plug fan then the LPHW heating coil is placed before the supply air fan 3 1 3 Unit construction DanX XK with separate mixing module The DanX XK consist of a cross flow h...

Страница 10: ...ation dampers only as it is easier now then after the unit has been assembled see drawing Check the rubber gaskets 2 at the end of each module that they are not damaged or loose This is important as i...

Страница 11: ...les are in level and in same height Use straps 1 to move the modules the last few millimetres Straps should only be mounted at the bottom or and top of the modules Connect neighbour modules by pushing...

Страница 12: ...nging filter modules Half height hanging filter modules are mounted on a set of support brackets to be found in a box inside the module Follow these steps for mounting the modules Screw the two bracke...

Страница 13: ...xible connection is used an earth connection must be mounted between unit and duct work 3 2 5 Outdoor unit Installation of outdoor and indoor units are done in the same way however outdoor units often...

Страница 14: ...e unit through the module joint a bridge must be mounted between the two drip trays of the modules This bridge is delivered separately and should be mounted when the modules are in place Place a strip...

Страница 15: ...r filling with water and check can be used for negative and positive pressure The length of the pipe can be calculated the following way Positive pressure H1 50 mm H2 p 50 mm Negative pressure H1 p 50...

Страница 16: ...lled in the supply air duct after the heating coil in the following way Drill an 8 mm hole in the supply air duct about 1 5 m from the unit Place the sensor in the hole Fasten the sensor housing to th...

Страница 17: ...ing are found in the fan section where they are stored under transport Unpack the frequency converters and mount them either on a special framework on the fan section or in another place next to the D...

Страница 18: ...4 Pump for water cooled condenser control signal from DanX control panel 5 Water consumption gauge 6 Regulation valve 7 Temperature sensor separate water temperature control with on off signal to DanX...

Страница 19: ...t exchanger counter hold with a suitable tool in order to avoid any damage to the pipes Mount the connections in a way that it is possible to access the heat exchanger for maintenance afterwards 3 3 1...

Страница 20: ...ss flow heat exchanger in combination with a compressor driven heat pump in the same module The DanX XWPS is using a minimum of outdoor air which is required for hygienic reasons in the pool hall To k...

Страница 21: ...For further explanations about the controls of this unit please refer to the manual of the control panel 4 1 3 Unit function DanX XK with separate mixing module The DanX XK consist of a cross flow hea...

Страница 22: ...motors stop the unit and check the air volume 4 2 1 Air volume measurement and setting If your centrifugal fan is equipped with a measuring probe accessory installed at the spider arm of the fan the...

Страница 23: ...ion has to be changed After calculating the right pulley seizes the pulleys can be changed in the following way Unscrew the two Allen screws 3 and pull off the pulley 2 by screwing one Allen screw int...

Страница 24: ...the front of the frequency converter is used to set up the frequency converter All displays of data are in the form of a six digit LED display 1 capable of showing one item of operating data continuou...

Страница 25: ...rrent See motor type plate do not change Parameter 106 Rated motor speed See motor type plate do not change Parameter 202 Max motor frequency Factory set do not change Parameter 204 Min reference Pa M...

Страница 26: ...fan are installed in a separate box below the electrical connection box for the fan motors The transducer factory settings should normally not be changed After installing the unit and before the first...

Страница 27: ...d be that the and tube have been switched when connecting to the pressure transducer The rest of the DIP switches are factory set as follows and should not been changed IMPORTANT When changing the DIP...

Страница 28: ...rotation direction of the compressor is correct Check this in the following way Start up the compressor and watch the HP gauge If there is no pressure rise shown on the HP gauge stop the compressor at...

Страница 29: ...ng to close Now set the outside air to 100 wait a few minutes and check if the dampers have taken the following positions Dehumidification damper 1 and recirculation damper 3 fully closed Outdoor damp...

Страница 30: ...ature set point and the outside air temperature of at least of 10 C so that the unit runs in heat recovery mode Now the dampers should be in the positions shown to the left in the picture below 100 re...

Страница 31: ...ollowing positions Recirculation damper 3 fully closed Outdoor damper 4 and exhaust air damper 2 fully open Now check the operation of the by pass damper 1 Make sure that there is a temperature differ...

Страница 32: ...ists or by people supervised by authorized staff It is the responsibility of the fitter to read and understand this guide and other given information 5 2 Maintenance plan Or when filter alarm is shown...

Страница 33: ...en centrifugal fans should be checked in the following way Check that the pulleys are placed correctly and in line Check if all bolts of the pulley are fastened Check the belts on wear and damage When...

Страница 34: ...handles 1 Take out the filters 2 and check the gasket on the filter rail for damage Clean the filter rail and reinstall the old new filters 5 6 Heating coil The following steps should be taken to mai...

Страница 35: ...he evaporator you may have to remove the drop catcher see 5 10 Straighten any bent slats using appropriate tools Check that the frost sensor is properly fixed in the evaporator coil The following step...

Страница 36: ...is dirty Filter blocked Change filter Flow error Fan belt broken Fan motor broken Damper not open Change belt Change repair motor Check damper motor Thermo relay switched off Fan motor broken Phase m...

Страница 37: ...set before the unit is started again Press the red button on the thermostat to reset The thermostats are located in the exhaust 70 C thermostat and supply 40 C air 3 For further explanations see the m...

Страница 38: ...be shut down before decommissioning and dismantling the equipment Make sure that no water glycol mixture is leaking Empty the heating coil for the water glycol mixture before removing it from the unit...

Страница 39: ...n 204 Minimum reference Pa Set pressure range of pressure transducer 4 3 3 205 Maximum reference Pa Set pressure range of pressure transducer 4 3 3 207 Ramp up time 1 60 sec 208 Ramp down time 1 60 se...

Отзывы: