Default Cooling strategies (can be changed using the CC3000 controller. ) 

TTL link 

The TTL link interface is used for service / test purposes.  
System status information  can be read out.
Configuration and settings can be changed.
Override function to verify correct connection of system components like Free cooling unit , 
dampers, sensors, etc.  
All configuration overrides are password protected.

Cooling strategy - example 

Содержание CC 3000

Страница 1: ...Upgrade kit CC3000 controller 28 02 2017 EN Part no 094838...

Страница 2: ...lity of property damage and or personal injury It is the responsibility of the installer to ensure the conformity of all not supplied cables towards national regulations Make sure that the power to th...

Страница 3: ...ing to national rules and procedures to protect the environment The CC3000 upgrade kit AC DC has the part number 094838 and is available in two versions CC3000 with Sat Box AC 230V to replace TKS 3000...

Страница 4: ...sensor to CC3000 place the sensor element at same place as present sensor The temperature sensors from ACUE and TKS3000 will not work with CC3000 7 Outdoor temperature sensor Connect the included temp...

Страница 5: ...stalling the CC3000 with Flexibox 450 and DFC 350 450 DC Satellite Box FB 450 DC Flexibox Cable Black 1 Black 3 Black 4 Black 2 Black 5 Black 6 48V DC Cable 8 wire included in upgrade kit Outdoor Sens...

Страница 6: ...Flexibox 450 and DFC 350 450 continued Flexibox Cable 1 Brown Blue Green yellow Flexibox Cable 2 Black 1 Black 2 Black 3 Black 6 Black 5 230V AC Cable 8 wire included in upgrade kit GND AC Satellite...

Страница 7: ...g the CC3000 with Flexibox 450 and DFC 350 450 continued Cable 8 wire included in upgrade kit DC Satellite Box Flexibox Cable Black 1 Black 3 Black 4 Black 2 Black 5 Black 6 DFC 350 450 DC 48V DC Outd...

Страница 8: ...exibox 450 and DFC 350 450 continued Flexibox Cable 1 Brown Blue Green yellow Flexibox Cable 2 Black 1 Black 2 Black 3 Black 6 Black 5 230V AC Cable 8 wire included in upgrade kit GND AC Satellite Box...

Страница 9: ...le trays Step 5 CC3000 Access connectors Fasten main part to the wall mount Press to release Remove front cover to access connectors Use two screws in the stand offs to secure the main part of the cas...

Страница 10: ...ensor to green connector J11 Pin No 1 and 2 System setup At startup insert SD card in the slot located on the side of the CC3000 controller This will allow you to select the config file for your free...

Страница 11: ...11...

Страница 12: ...is used for service test purposes System status information can be read out Configuration and settings can be changed Override function to verify correct connection of system components like Free cool...

Страница 13: ...Temperature at bottom of P band 25 Max C Temperature at top of P band 29 SetPoint The wanted indoor temperature fan speed will be adjusted between Min C and Max C 27 Emergency on Fan run 100 38 Emerge...

Страница 14: ...rnal Air Con unit 1 stops if connected 29 A C 2 on External Air Con unit 2 start if connected 33 A C 2 off External Air Con unit 2 stops if connected 31 Emergency on Fan run 100 and both A C 1 and A C...

Страница 15: ...ternal Air Con unit 1 stops if connected 29 A C 2 on External Air Con unit 2 start if connected 33 A C 2 off External Air Con unit 2 stops if connected 31 Emergency on Fan run 100 and both A C 1 and A...

Страница 16: ...Con unit 2 start if connected 29 A C 2 off External Air Con unit 2 stops if connected 27 Emergency on Fan run 100 and both A C 1 and A C 2 starts 38 Emergency off Fan stops both A C 1 and A C 2 conti...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...No 094838 2006 42 EC Directive on the safety of machines 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2011 65 EU RoHS Directive and is manufactured in conformity with the following harmon...

Страница 20: ...ad Clevedon North Somerset BS21 6SR England Phone 44 0 1275 87 68 51 Fax 44 0 1275 34 30 86 infouk dantherm com www dantherm co uk Dantherm Cooling A S 4th Dobryninskiy Lane 8 Office C 11 01 119049 Mo...

Отзывы: