FAN MOTORS:

  C

lean the in-take on CONVECTION (ROOM AIR) fan as well as the air holes on the 

motors of both COMBUSTION and CONVECTION fans annually.   

  

FRESH AIR INTAKE

:

  Inspect periodically to be sure that it is not clogged with any foreign materials.  A 

plugged screen will restrict or shut off combustion air and cause a fire to die or burn poorly. 

  

GOLD / BRASS / NICKEL /PEWTER TRIM CLEANING:

 

Use a damp cloth to clean your door. 

DO NOT USE ANY ABRASIVE CLEANERS AS YOU WILL REMOVE OR SCRATCH THE PLATING!

 

 

 

  

CHECK AND CLEAN THE HOPPER

 

Check the hopper periodically to determine if there is any sawdust or pellets that are sticking to  
the hopper surface. Clean as needed. An excess build up of fines, will lead to improper feeding and possible 
auger jams.    

HINT: 

To aid in the fuel sliding easily down to the auger, you can wipe down the inside of the hopper with a car  

wax. 

 

GASKET INSPECTION:   

 Air leaks into the firebox will decrease the appliance’s performance greatly, 

leading to excessive sooting inefficient burning and perhaps a malfunction.  

 

 

Door Gasket

—Inspect the door gasket to make sure it is fully attached.  Use stove gasket cement to re-attach 

if necessary.  If the door gasket is worn, badly torn or flattened, replace. 

 

Ash Pan

—Remove the ashpan and inspect the gasket around the perimeter of the pan.  Re-attach or replace 

the gasket if necessary. 

 

Glass Gasket

— There is no gasket across the top or bottom edges of the glass.  This is to allow for air wash. 

Check these areas for build-up or obstructions and clean as needed.  The gasketing found on either side edge 
of the glass does go completely around the corners on the top and bottom to act as a spacer for the glass. 
If replacing this gasket, ensure the gasket covers the entire side and approximately 1 inch of the top and  
bottom edges.. 

 

GLASS CLEANING :

 We recommend using a high quality fireplace or stove glass cleaner or a vinegar 

and water solution along with a rag. Oven cleaner and window cleaners will leave a film on the glass that will 
attract smoke and creosote like a magnet. Should a build up of creosote or carbon accumulate you may wish 
to use 000 steel wool and water to clean glass. Ceramic is very hard and will not scratch from the steel wool.  

 

GLASS REPLACEMENT:

 In the event you need replacement only Hi-Temp Neo-Ceram of the correct 

size and thickness may be used. Contact your local

 

Glow Boy SERIES

 

dealer to obtain this glass.  

DO NOT OPERATE STOVE WITH BROKEN GLASS AS LEAKAGE OF FLUE GASES MAY RESULT. 

 

PAINTED SURFACES:

 

Painted surfaces may be wiped down with a damp cloth. If scratches appear or 

you wish to renew your paint, contact your Dealer to obtain a can of Satin Black (“Stove Bright”) paint.  

 

Tip: 

use a hair dryer to warm the surface prior to touching up the paint, this helps to reduce paint runs. 

Note: Do not use any other brand other than “Stove Bright” as they may not be compatible.

 

FALL START UP

:

  Prior to lighting the first fire check the outside area around the exhaust and air intake 

systems for obstructions.  Clean the screens on the exhaust system and the outside air intake pipe.  Turn all 
controls on to make sure they are working prior to lighting the first fire. Clean and remove fly ash from exhaust 
venting.   

 

SPRING SHUTDOWN:

  [COLD STOVE AND COLD ASHES ONLY]

.  After the last burn in the spring 

remove pellets from the hopper and the auger.  Scoop out the pellets then run the auger until the hopper is 
empty and pellets stop flowing.  Vacuum out the hopper.  Thoroughly clean the burn grate, burn box, ashtray 
and ash traps.  It’s desirable to spray the inside of the cleaned hopper with an aerosol silicone spray if your 
stove is in a high humidity area.  The 

exhaust system

 should be thoroughly cleaned.   

Disassemble the EXHAUST FAN and CONVECTION FAN  and clean off the internal fan blades. 
Once you are finished, unplug the appliance for added electrical protection. 

M

M

AINTENANCE

AINTENANCE

 

 

P

P

ERIODIC

ERIODIC

 

 

C

C

LEANING

LEANING

  

   

Glow Boy  Pellet & Biomass               

              www.glowboystoves.com               35 

 

Содержание GLOW BOY FGB

Страница 1: ...Solid Fuel Burning Appliances and Equipment in Canada and NFPA 211 Chimney Fireplaces Vents and Solid Fuel Burning Appliances in th e USA Contact local building or fire officials about restrictions a...

Страница 2: ...reatly from company to company from load to load and occasionally from bag to bag 4 Be extra 5 Remember that most operational dilemmas with a pellet stove are usually traced back to Improper installat...

Страница 3: ...E 10 LIMITED WARRANTY 40 SAFETY PRECAUTIONS DETERMING SIZE DISTANCE 11 TERMINATION 12 PLANNING OUTSIDE AIR 13 APPLIANCE PLACEMENT 14 FLOOR PROTECTION CLEARANCES TO COMBUSTIBLES INSTALLATION TOOLS OF T...

Страница 4: ...ppliance Keep all such liquids well away from the appliance while it is in use This heater must be connected to a standard 115 V 60 Hz 3 prong grounded electrical outlet in accor dance with local buil...

Страница 5: ...ner with a tight lid and placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked twice a year minimum...

Страница 6: ...t of your stove along with gases into the atmosphere Your stove s heat output can be adjusted from setting 1 4 through the FEED RATE touch pad to vary your heat output from Low to High The room air fa...

Страница 7: ...H Your pellet appliance has a high temperature limit switch installed If the temperature at the back of the firebox reaches approximately 250 F the switch will shut off the electricity going to the Va...

Страница 8: ...ty Bay View Freestanding 60 lbs Approx Burn time at lowest setting 48 hrs Hopper Capacity Bay View Insert Built in 40 60 lbs Approx Burn time at lowest setting 27 48 Hopper Capacity Freestanding Step...

Страница 9: ...hand for warranty COMPLETE THIS CHECK LIST WHILE INSTALLING YOUR MULT FUEL APPLIANCE _____ Carefully read the ENTIRE installation section first Twice is better _____ Read the Installing Freestanding...

Страница 10: ...vent VENT SAFETY PRECAUTIONS A Clean Out Tee 4 must be installed at the bottom of all vertical runs These Tee s are to assist in periodically cleaning the vent Single or Double clean out tees may be u...

Страница 11: ...quivalent and the Altitude above sea level NOTE In some cases it may be necessary to contact Dansons Customer Service personal to determine acceptable venting configurations and altitude adjustments 1...

Страница 12: ...Minimum 1 clearance above any door or window that opens C Minimum 3 clearance from any adjacent building D Minimum 7 clearance above any grade when adjacent to public walkways E Minimum 2 clearance a...

Страница 13: ...st 1 foot away from the exhaust system termination When outside air is taken from an existing chimney the exhaust system must not terminate in the same chimney The outside air pipe on your stove is 2...

Страница 14: ...the section Alcove Installation Stove and floor protection must be installed on a level secure floor NOTE It is important for your appliance to be level Leveling should occur below the floor protectio...

Страница 15: ...in depth depending on the brand of PL vent used Before placing the stove connect the Tee and measure off the 3 clearance ALCOVE INSTALLATION Minimum clearances to combustibles Figure 14 15 2 inch from...

Страница 16: ...ts Flashlight Wire stripper and wire cutter Hammer Bubble Level Utility knife Adjustable pliers 6 to 8 inches Small hand broom and dustpan Furniture and Floor Protection Supplies Caulking tube of RTV...

Страница 17: ...7 16 nuts supplied and secure tightly 6 Place a bead of RTV silicone around the end collar of the Quick Connect of your stove s exhaust C Firmly push the PL vent pipe adaptor J into the bead of RTV si...

Страница 18: ...ent outside air source with a inch screen over the inlet Figure 26 B C D For transportation all chimney vent above the mobile home must be removed Chimney PL Vent must be 3 or 4 PL Vent and must exten...

Страница 19: ...n case of power failure Follow the same basic steps in locating your appliance attaching the exhaust system and outside air intake to your stove as the previous examples 1 2 3 4 5 6 7 8 Main Floor Ver...

Страница 20: ...610 Clearances obtained from the masonry fireplace tests are also relevant for installation in factory built fireplaces Installation must include a full height listed chimney liner meeting type HT req...

Страница 21: ...HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO RE USE AS A CONVENTIONAL FIREPLACE When installing into a masonry chimney it is recommended t...

Страница 22: ...directly into a wall as either a horizontal or vertical vent installation see figure 27 28 The exhaust installation requirements are the same as for a freestanding stove Refer to Installing Freestand...

Страница 23: ...re building another room to your home You want it to be as energy efficient as the rest of your home Minimum Required Traditional Unit Only Traditional Minimum BayView Unit Only Side Clearance 3 in 22...

Страница 24: ...over FINE TUNNING YOUR STOVE later in this manual OPENING AND CLOSING THE MAIN DOOR Open the stove door by rotating the handle COUNTER CLOCKWISE toward the TOP of the stove until the handle is about t...

Страница 25: ...rmal operating temperatures your stove will continue to run If the fire does not light and or burn properly the electricity to your stove s components will be shut off at the end of 15 minutes The FAN...

Страница 26: ...4 Lights Feed Rates 3 4 Feed Rates 1 4 Only be concerned with the lights All others do not effect the mode selection process FEED RATE NOTE The Starting Point of the cycle depends on what mode the co...

Страница 27: ...at 1 cycle When the temperature in the room drops to the level set at the thermostat the stove will again cycle to the HIGH 2 3 or 4 preselected set ting For optimum heat transfer the FAN setting shou...

Страница 28: ...he stove off Feed Rates 1 2 U UNDERSTANDING NDERSTANDING T THE HE C CONTROL ONTROL HI MED LOW FAN SPEED OFF FAN SPEED AUGER CYCLE Glow Boy Pellet Biomass www glowboystoves com 28 FINE TUNE ADJUSTMENTS...

Страница 29: ...ED RATE or START touch pad The COMBUSTION FAN exhaust will start and operate at full speed for 60 seconds then adjust downward to match feed rate 1 The CONVECTION FAN heating will start and the LED wi...

Страница 30: ...NLET DAMPER This will have to be set as the factory can not send the units out with the damper pre set This is done to accommodate a wide range of installations elevations and fuel type and quality Sl...

Страница 31: ...tput and visa versa Pellet feed rate at the same fuel settings may vary greatly from brand to brand and may vary somewhat from batch to batch within the same brand FINES FINES in pellets are pieces of...

Страница 32: ...next heating season unless properly stored If you do decide to carry it over make sure to check the corn for proper moisture content FACTORS EFFECTING FEED RATES Generally the smaller and cleaner free...

Страница 33: ...n grate Clean out the burn pot area of all debris CAUTION When replacing the grate make sure it fits properly in the burn pot WINDOW CLEANING COLD STOVE ONLY as hot glass may cause serious burns To en...

Страница 34: ...e DOOR GASKET Inspect the main door gasket periodically The main door may be removed to have frayed broken or compacted gaskets replaced EXHAUST VENTING The by products of combustion contain small par...

Страница 35: ...egar and water solution along with a rag Oven cleaner and window cleaners will leave a film on the glass that will attract smoke and creosote like a magnet Should a build up of creosote or carbon accu...

Страница 36: ...OBLEM CAUSE SOLUTION Stove Will Not Start 1 No electrical power Ensure the stove is plugged in to a 120VAC electrical outlet and a Surge Protection unit Check outlet for electrical power and proper vo...

Страница 37: ...Remove all ash and clinkers Ensure air holes are free of debris or build up 3 Igniter is not glowing Remove burn grate close door and re start the appliance If the igniter does not glow red inside th...

Страница 38: ...e or smoke smell spillage 1 Exhaust System Hi Heat RTV silicone all joints even manufactured Ensure venting is gas tight Inspect exhaust fan and gasket area ensure a tight fit Proper maintenance and c...

Страница 39: ...haft Assembly KS5080 1240 Burn Grate Super Grate KS5020 1040 Combustion Fan w gasket KS5020 1070 Convection Fan w gasket KS5040 1090 Control Board AcuTron 2 Door Assembly black Door Assembly brass tri...

Страница 40: ...Burning other than quality wood pellets may void the warranty The warranty does not cover damage or breakage due to misuse improper handling or modifications The limited warranty registration card mu...

Отзывы: