background image

 29 

O

O

PERATING

PERATING

 

 

I

I

NSTRUCTION

NSTRUCTION

 

 

L

L

IGHTING

IGHTING

 

 

Y

Y

OUR

OUR

 

 

A

A

PPLIANCE

PPLIANCE

 

Before lighting a fire check to ensure the Burn Grate is clean and adjusted and the Ash Tray is not full. 

For safety reasons use extra caution when lighting a stove that is HOT! 

Lighting stove manually (No Igniter)

 

In the NON-Thermostat Mode

 

 

 

Lighting stove with Auto-Ignitor

 

In the NON-Thermostat Mode

 

 

 

1. Push firmly on the 

FEED RATE or START

 touch pad.   

-The 

 COMBUSTION FAN 

(exhaust) will start and op-

erate at full speed for 60 seconds, then adjust down-
ward to match feed rate #1

 

-The 

CONVECTION FAN 

(heating) will start and the 

LED will go solid on LOW setting

 

- The 

AUGER CYCLE 

LED

 

will go solid for 3 seconds, 

indicating signal being sent to auger motor.

 

 

 

2. Place a small amount of a solid fuel fire starter, such

 

    as those made from sawdust and wax or use wood

 

    shavings, in the bottom of the burn grate.

 

   Add a small handful of pellets to the starter material.

 

   Add a small amount of fire starter over the pellets.

 

 

 

CAUTION:  DO NOT USE ANY FLAMMABLE 
LIQUIDS SUCH AS GASOLINE, GASOLINE-TYPE 
LANTERN FUEL, KEROSENE, CHARCOAL 
LIGHTER FLUID, OR SIMILAR LIQUIDS TO START 
OR FRESHEN-UP THE FIRE!  KEEP ALL SUCH 
LIQUIDS WELL AWAY FROM THE HEATER 
WHILE IT IS IN USE.

 

 

 

3. Light the fire starter and slowly close the 

MAIN

 

    DOOR

, leaving it about 1 inch open.  When the

 

    pellets are burning, close and latch the main door. If

 

    the fire goes out when the main door is closed, add

 

    more fire starter, re-light the fire and leave the main

 

    door open an inch or so until the pellets start to burn,

 

    then close and latch the main door.

 

 

 

4. Adjust the 

FUEL RATE

 and the 

FAN

 

SPEED

 to your 

desired settings you require upon completion of 
startup sequence.

 

 

 

 

 

1. Push firmly on the 

FEED RATE or START

 

touch pad.

 

 -The 

 COMBUSTION FAN 

(exhaust) will start   

and operate at full speed for 60 seconds, then 
adjust downward to match feed rate #1

 

 -The 

CONVECTION FAN 

(heating) will start  

and the LED will go solid on LOW setting

 

- The 

AUGER CYCLE 

LED

 

will go solid for 3 

seconds, indicating signal being sent to auger 
motor.

 

-The 

IGNITER

 LED will light up solid and the 

300 watt igniter will begin to operate.

 

 

 

2. On a primed 

AUGER

 system pellets will begin 

to fall into the 

BURN GRATE

, and the 

AUTO 

SELF IGNITER 

will automatically ignite the 

pellets in approx. 3 – 5 min.

 

 

 

Note: If stoves fails to light within 15 minutes, 
shut off the stove, remove the pellets from the 
burn grate and repeat step 2.  If stove fails to 
ignite a second time, disconnect and contact 
your dealer

.

 

 

 

3.  Adjust the 

FUEL RATE

 and the 

FAN

 

SPEED

 

to your desired settings you require upon 
completion of startup sequence.

 

 

 

 

 

 

 

 

 

CAUTION:

 

Never use liquid or volatile fire starters to start a fire in your stove

!  Do not in-stall or operate 

your stove in any room where any liquid or volatile fuels or any other highly combustible items are in the air or 
stored in the room.  These could cause a safety hazard.  

NOTE:

  If the fire does not start, your stove will continue to feed pellets and the fans will run for approxi-

mately 15 minutes. The stove will then automatically shut off.  If this happens, some unburned pellets will 
build up in the burn grate.  To restart the fire, clean the excess pellets out of the burn grate and follow the 
above "Lighting a Fire". 

NOTE:

  Some odors may be given off a new stove during the initial few hours of burning while the stove 

and the paint are being cured.  These odors are not harmful.  However, ventilating the room until the odors 
disappear is strongly recommended. Run your appliance on HIGH #4 setting and turn off the room heating 
fan for approximately 1/2 hour, to quickly aid in limiting these odors. 

Glow Boy  Pellet & Biomass        

                      www.glowboystoves.com               29 

 

Содержание GLOW BOY FGB

Страница 1: ...Solid Fuel Burning Appliances and Equipment in Canada and NFPA 211 Chimney Fireplaces Vents and Solid Fuel Burning Appliances in th e USA Contact local building or fire officials about restrictions a...

Страница 2: ...reatly from company to company from load to load and occasionally from bag to bag 4 Be extra 5 Remember that most operational dilemmas with a pellet stove are usually traced back to Improper installat...

Страница 3: ...E 10 LIMITED WARRANTY 40 SAFETY PRECAUTIONS DETERMING SIZE DISTANCE 11 TERMINATION 12 PLANNING OUTSIDE AIR 13 APPLIANCE PLACEMENT 14 FLOOR PROTECTION CLEARANCES TO COMBUSTIBLES INSTALLATION TOOLS OF T...

Страница 4: ...ppliance Keep all such liquids well away from the appliance while it is in use This heater must be connected to a standard 115 V 60 Hz 3 prong grounded electrical outlet in accor dance with local buil...

Страница 5: ...ner with a tight lid and placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked twice a year minimum...

Страница 6: ...t of your stove along with gases into the atmosphere Your stove s heat output can be adjusted from setting 1 4 through the FEED RATE touch pad to vary your heat output from Low to High The room air fa...

Страница 7: ...H Your pellet appliance has a high temperature limit switch installed If the temperature at the back of the firebox reaches approximately 250 F the switch will shut off the electricity going to the Va...

Страница 8: ...ty Bay View Freestanding 60 lbs Approx Burn time at lowest setting 48 hrs Hopper Capacity Bay View Insert Built in 40 60 lbs Approx Burn time at lowest setting 27 48 Hopper Capacity Freestanding Step...

Страница 9: ...hand for warranty COMPLETE THIS CHECK LIST WHILE INSTALLING YOUR MULT FUEL APPLIANCE _____ Carefully read the ENTIRE installation section first Twice is better _____ Read the Installing Freestanding...

Страница 10: ...vent VENT SAFETY PRECAUTIONS A Clean Out Tee 4 must be installed at the bottom of all vertical runs These Tee s are to assist in periodically cleaning the vent Single or Double clean out tees may be u...

Страница 11: ...quivalent and the Altitude above sea level NOTE In some cases it may be necessary to contact Dansons Customer Service personal to determine acceptable venting configurations and altitude adjustments 1...

Страница 12: ...Minimum 1 clearance above any door or window that opens C Minimum 3 clearance from any adjacent building D Minimum 7 clearance above any grade when adjacent to public walkways E Minimum 2 clearance a...

Страница 13: ...st 1 foot away from the exhaust system termination When outside air is taken from an existing chimney the exhaust system must not terminate in the same chimney The outside air pipe on your stove is 2...

Страница 14: ...the section Alcove Installation Stove and floor protection must be installed on a level secure floor NOTE It is important for your appliance to be level Leveling should occur below the floor protectio...

Страница 15: ...in depth depending on the brand of PL vent used Before placing the stove connect the Tee and measure off the 3 clearance ALCOVE INSTALLATION Minimum clearances to combustibles Figure 14 15 2 inch from...

Страница 16: ...ts Flashlight Wire stripper and wire cutter Hammer Bubble Level Utility knife Adjustable pliers 6 to 8 inches Small hand broom and dustpan Furniture and Floor Protection Supplies Caulking tube of RTV...

Страница 17: ...7 16 nuts supplied and secure tightly 6 Place a bead of RTV silicone around the end collar of the Quick Connect of your stove s exhaust C Firmly push the PL vent pipe adaptor J into the bead of RTV si...

Страница 18: ...ent outside air source with a inch screen over the inlet Figure 26 B C D For transportation all chimney vent above the mobile home must be removed Chimney PL Vent must be 3 or 4 PL Vent and must exten...

Страница 19: ...n case of power failure Follow the same basic steps in locating your appliance attaching the exhaust system and outside air intake to your stove as the previous examples 1 2 3 4 5 6 7 8 Main Floor Ver...

Страница 20: ...610 Clearances obtained from the masonry fireplace tests are also relevant for installation in factory built fireplaces Installation must include a full height listed chimney liner meeting type HT req...

Страница 21: ...HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO RE USE AS A CONVENTIONAL FIREPLACE When installing into a masonry chimney it is recommended t...

Страница 22: ...directly into a wall as either a horizontal or vertical vent installation see figure 27 28 The exhaust installation requirements are the same as for a freestanding stove Refer to Installing Freestand...

Страница 23: ...re building another room to your home You want it to be as energy efficient as the rest of your home Minimum Required Traditional Unit Only Traditional Minimum BayView Unit Only Side Clearance 3 in 22...

Страница 24: ...over FINE TUNNING YOUR STOVE later in this manual OPENING AND CLOSING THE MAIN DOOR Open the stove door by rotating the handle COUNTER CLOCKWISE toward the TOP of the stove until the handle is about t...

Страница 25: ...rmal operating temperatures your stove will continue to run If the fire does not light and or burn properly the electricity to your stove s components will be shut off at the end of 15 minutes The FAN...

Страница 26: ...4 Lights Feed Rates 3 4 Feed Rates 1 4 Only be concerned with the lights All others do not effect the mode selection process FEED RATE NOTE The Starting Point of the cycle depends on what mode the co...

Страница 27: ...at 1 cycle When the temperature in the room drops to the level set at the thermostat the stove will again cycle to the HIGH 2 3 or 4 preselected set ting For optimum heat transfer the FAN setting shou...

Страница 28: ...he stove off Feed Rates 1 2 U UNDERSTANDING NDERSTANDING T THE HE C CONTROL ONTROL HI MED LOW FAN SPEED OFF FAN SPEED AUGER CYCLE Glow Boy Pellet Biomass www glowboystoves com 28 FINE TUNE ADJUSTMENTS...

Страница 29: ...ED RATE or START touch pad The COMBUSTION FAN exhaust will start and operate at full speed for 60 seconds then adjust downward to match feed rate 1 The CONVECTION FAN heating will start and the LED wi...

Страница 30: ...NLET DAMPER This will have to be set as the factory can not send the units out with the damper pre set This is done to accommodate a wide range of installations elevations and fuel type and quality Sl...

Страница 31: ...tput and visa versa Pellet feed rate at the same fuel settings may vary greatly from brand to brand and may vary somewhat from batch to batch within the same brand FINES FINES in pellets are pieces of...

Страница 32: ...next heating season unless properly stored If you do decide to carry it over make sure to check the corn for proper moisture content FACTORS EFFECTING FEED RATES Generally the smaller and cleaner free...

Страница 33: ...n grate Clean out the burn pot area of all debris CAUTION When replacing the grate make sure it fits properly in the burn pot WINDOW CLEANING COLD STOVE ONLY as hot glass may cause serious burns To en...

Страница 34: ...e DOOR GASKET Inspect the main door gasket periodically The main door may be removed to have frayed broken or compacted gaskets replaced EXHAUST VENTING The by products of combustion contain small par...

Страница 35: ...egar and water solution along with a rag Oven cleaner and window cleaners will leave a film on the glass that will attract smoke and creosote like a magnet Should a build up of creosote or carbon accu...

Страница 36: ...OBLEM CAUSE SOLUTION Stove Will Not Start 1 No electrical power Ensure the stove is plugged in to a 120VAC electrical outlet and a Surge Protection unit Check outlet for electrical power and proper vo...

Страница 37: ...Remove all ash and clinkers Ensure air holes are free of debris or build up 3 Igniter is not glowing Remove burn grate close door and re start the appliance If the igniter does not glow red inside th...

Страница 38: ...e or smoke smell spillage 1 Exhaust System Hi Heat RTV silicone all joints even manufactured Ensure venting is gas tight Inspect exhaust fan and gasket area ensure a tight fit Proper maintenance and c...

Страница 39: ...haft Assembly KS5080 1240 Burn Grate Super Grate KS5020 1040 Combustion Fan w gasket KS5020 1070 Convection Fan w gasket KS5040 1090 Control Board AcuTron 2 Door Assembly black Door Assembly brass tri...

Страница 40: ...Burning other than quality wood pellets may void the warranty The warranty does not cover damage or breakage due to misuse improper handling or modifications The limited warranty registration card mu...

Отзывы: