Thermal Capacity
– How much of the available thermal capacity has been used
Driver Current
(for each output) – The average current being delivered to the driver
Driver Impedance
(for each output) – The average impedance of the driver
Protection Limiting
(for each output) -‐ How much the amplifier is ‘dimming’ itself in order to protect
itself from potential damage
The data in the log can be exported by right-‐clicking on the log to launch a context menu, and
selecting “copy log data to clipboard”. The data could then be pasted into a spread sheet for further
analysis. Your dealer may ask you to do this is you have experienced a problem.
Alternatively, all of the operational and performance data, including the logs may be collected
together into a single file by selecting File > Save Device Diagnostics. Your dealer will be able to read
and interpret this data.