PORTABLE COLL-O-CRIMP® Model T-400-1 Set up and operating instructions

7 | PORTABLE COLL-O-CRIMP® Model T-400-1 Set up and operating instructions | 2022.10.

AQ430855066686en-000101

Mobile Set-Up Instructions

INTRODUCTION: 

T-412 is designed for use with the Coll-O-Crimp I machine. See page 4 for specifications. Due to the mobile equipment application, caution 

must be taken when installing the DC unit. Adequate wiring is imperative for proper operation. If the battery is grounded to the engine, make sure the engine 
is grounded to the frame of the vehicle with the same wire gauge used for the power unit cable. Attach the positive cable to the positive battery terminal. 
Connect the opposite end of the positive cable to the power unit solenoid start switch while the DC unit is in operation. The vehicle’s engine must be running 
to avoid battery discharge. Remember, the battery ground to the engine only is not sufficient. (See Diagram ‘B’ below). The current draw is several hundred 
amperes, so adequate wire size and battery capacity is absolutely essential. (See Diagram ‘A’ below). Direct wire ground to battery. Welding cable recommended.

Set Up Instructions:

The following method of setting up your Coll-O-Crimp equipment package is offered as a guide and may be varied to suit your needs.

1.  

Before opening any shipping cartons, be sure proper grounding and 
wiring are used (See Diagram ‘A’ below).

 a. 

 

Checkfor a proper ground path. Aground from the battery to 
only the engine is not sufficient. Be sure the battery is grounded 
to the frame of the vehicle with the same gauge wire as the 
cable required for the pump. (See Diagram ‘B’ below).

 b. 

 

The pump must be grounded to the vehicle frame and not to the 
body. There are two 3/8-18 UNC tapped holes in the bottom of the 
pump housing for mounting the pump to the vehicle frame.

 c. 

 

Since current draw can exceed 200 amperes during the crimping 
cycle, adequate wire size is essential. Number 4 gauge wire is 
required for a cable length of up to 20 feet from the battery to the 
pump. Number 2 gauge wire is required for a cable length between 
20 and 40 feet from the battery to the pump (see Diagram ‘A’ below).

 d. 

 

The 12 volt battery should have an ampere-hours rating of at 
least 70 and have a minimum of 11 plates per cell. For constant 
usage, when a large number of hose assemblies are to crimped, 
it would be appropriate during crimping to run the engine at a 
fast idle to maintain battery charge.

2.    

Open the shipping cartons and remove all equipment and components.

3.    

Prepare the mounting surface or surfaces for the Coll-O-Crimp press 
and the DC pump. NOTE: Care should be taken to insure that the press 
mounting surface is capable of supporting 113 pounds. The front edge 
of the press will extend 8-5/8 inches beyond the edge of the mounting 
surface. Figure 1, page 6, shows atypical bench layout forthe crimper. 
Figure 2, page 6, shows a typical equipment set up with the DC Pump.

4.

 

 

Bolt the press to the mounting surface using 1/2 inch bolts.

5.

 

 

Remove the plug from the top of the press and connect the 4205X6X6 
adapter from the hose assembly (T-400-21). This adapter can be 
adjusted easily for the best alignment of the hose assembly after the 
pump is mounted.

6

.  

Place the T-412 DC pump on a properly grounded mounting surface 
within convenient working distance of the press. Remove the plug 
from the pressure port from the top-center of the pump housing and 
connect the 4315X6X8 adapter from the hose assembly (T-400-21). 
Loosely connect the T-400-21 hose assembly to the adapters in the 
press and pump. Locate the pump so that the hose will appear as 
shown in Figure 2, page 6.

7.

 

 

Locate and drill mounting holes forthe pump. There are two 3/8-16 UNC 
tapped holes, 1/2 inch deep and five inches apart in the bottom of the 
pump housing.

8.

 

 

Bolt the pump to the mounting surfaces.

9.

 

 

Tighten the hose connections.

Check once again to be sure the pump and battery are properly grounded 
to the vehicle frame.

Run a #1, #4 or #2 gauge wire power cable directly from the ‘hot side’ of 
the battery, or the ‘hot side’ of the engine starter solenoid, to the solenoid 
start switch on the pump. The solenoid start switch is strap mounted to 
the outside of the DC motor. The proper connection is the top post on the 
solenoid which also has a small wire going into the actuator mounting box 
on the side of the pump housing.

DIAGRAM 'A'

Minimum Wire Gauge & Battery Size

Total Length of Cable

12 Volt Battery

15 ft.

20 ft.

30 ft.

40 ft.

50 ft.

60 ft.

70 ft.

80 ft.

Number Plates/Cell

Amp. Hours

#4

#4

#2

#2

#1

#0

#0

#00

11

70

!

 NOTE

 If battery is grounded to engine, make 

sure engine is grounded to frame with same gauge 
of wire as power unit cable.

Installation Diagram “B” for T-412. 12 volt  

DC power unit for Coll-O-Crimp T-400-1

Содержание Weatherhead Coll-0-Crimp T-400-1

Страница 1: ......

Страница 2: ...is ordered the T 400 16 is supplied T 400 16 36 Hose assembly fittings for use with T 401 1 and T 411 Electric Pump T 400 18 108 Hose assembly fittings for use with T 402 1 Air Hydraulic Pump T 400 1...

Страница 3: ...provided with kit 2 Add the washer provided with the kit to existing washer as shown and torque the bolt down to approximately 75ft lbs 3 Attach the locator post of the pre assembled locator to the bo...

Страница 4: ...r Size 58 cu in Outlet Port Size 3 8 NPT Hydraulic Oil Automatic Transmission Fluid ATF or equivalent Reservoir Capacity 1 quart 1 412 Mobile Electric Pump Dimensions 7 1 2 high 9 wide 14 1 8 long Wei...

Страница 5: ...s are threaded from underneath Tighten STEP 4 T 421U Electric Pump Mount on top right side of cabinet Predrilled holes align the pump Insert bolts from top of cabinet Washers and nuts are installed fr...

Страница 6: ...capable of supporting the weight of the press approximately 113 lbs which extends 8 5 8 over the front edge of the mounting surface 3 Bolt T 421 U press to the mounting surface 4 Place power unit on...

Страница 7: ...constant usage when a large number of hose assemblies are to crimped it would be appropriate during crimping to run the engine at a fast idle to maintain battery charge 2 Open the shipping cartons an...

Страница 8: ...ricator be installed near the pump air inlet Ref page 4 forWeatherhead lubricator If a lubricator is not used place 3 or 4 drops of a high grade oil directly into the air inlet port weekly 2 Turn on a...

Страница 9: ...ge 10 4 Insert hose assembly from below between collet halves Align the dimples on the hose end collar with the top of the collet When using 757 Series ends the collar should be flush with the top of...

Страница 10: ...ss the pressed flat portion of the crimp NOTE In the larger sizes calipers may be used however in the smaller sizes and in the E Series thermoplastic hose ends a point micrometer will provide an accur...

Страница 11: ...ss shroud with decals 4 T 432 15 Pusher Not Shown T 400 13 Replacement collet cage for 1 400 U series collet with a C suffix 1 4 3 8 sizes only 2 required for each collet Not Shown T 400 14 Replacemen...

Страница 12: ...sheared Pump unload valve stuck open Step 4 Replace Pump Motor runs Pusher advances but doesn t develop final crimp pressure blows fuse Pump unload valve stuck shut Replace Pump Motor runs Pusher adva...

Страница 13: ...om bottoming Remove 3 8 NPTF plug from port above checkvalve and install a 6000 PSI pressure gauge With 6000 PSI pressure gauge in place operate unit to full crimping position Gauge should read 4000 4...

Страница 14: ...mbly equipment and stock into one convenient location The sturdy FH 135X cabinet contains 50 heavy duty plastic drawers that can be divided into one two orthree compartments allowing you ample space f...

Страница 15: ...ons FC Danfoss hoses fittings and tooling provide the ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable futu...

Отзывы: