0-20 Display Line 1.1 Small
Option:
Function:
[2316]
Maintenance Text
[2580]
Cascade Status
Status for the operation of the
Cascade Controller
[2581]
Pump Status
Status for the operation of each
individual pump controlled by the
Cascade Controller
[3110]
Bypass Status
Word
[3111]
Bypass Running
Hours
[9913]
Idle time
[9914]
Paramdb requests
in queue
[9920]
HS Temp. (PC1)
[9921]
HS Temp. (PC2)
[9922]
HS Temp. (PC3)
[9923]
HS Temp. (PC4)
[9924]
HS Temp. (PC5)
[9925]
HS Temp. (PC6)
[9926]
HS Temp. (PC7)
[9927]
HS Temp. (PC8)
0-21 Display Line 1.2 Small
Select a variable for display in line 1, middle position.
Option:
Function:
[1614]
*
Motor Current The options are the same as those listed
in
.
0-22 Display Line 1.3 Small
Select a variable for display in line 1, right position.
Option:
Function:
[1610]
*
Power [kW] The options are the same as those listed in
.
0-23 Display Line 2 Large
Select a variable for display in line 2.
Option:
Function:
[1613]
*
Frequency The options are the same as those listed in
0-24 Display Line 3 Large
Select a variable for display in line 3.
Option:
Function:
[30121]
*
Mains Frequency The options are the same as those
listed in
.
0-25 My Personal Menu
Array [20]
Range:
Function:
Size
related
*
[0 -
9999 ]
Define up to 20 parameters to appear in the
Q1 Personal Menu, accessible via the [Quick
Menu] key on the LCP. The parameters will
be displayed in the Q1 Personal Menu in the
order they are programmed into this array
parameter. Delete parameters by setting the
value to ‘0000’.
For example, this can be used to provide
quick, simple access to just one or up to 20
parameters which require changing on a
regular basis (e.g. for plant maintenance
reasons) or by an OEM to enable simple
commissioning of their equipment.
3.2.4 0-3* LCP Custom Readout
It is possible to customize the display elements for various
purposes: *Custom Readout. Value proportional to speed
(Linear, squared or cubed depending on unit selected in
) *Display Text. Text string stored in
a parameter.
Custom Readout
The calculated value to be displayed is based on settings in
(linear only),
,
,
4-14 Motor Speed High Limit [Hz]
and
actual speed.
130B
T105.11
0
Custom Readout (Value)
P 16-09
Custom Readout
Unit P 0-30
Max value
P 0-32
Min value
P 0-31
Motor Speed
Motor Speed
High limit
P 4-13 (RPM)
P 4-14 (Hz)
Linear Unit (e
.g. Speed and flo
w)
Quadr
atic Unit (P
ressur
e)
Cubic Unit (P
ow
er)
Liniar
units only
The relation will depend on the type of unit selected in
Parameter Description
VLT
®
HVAC Drive Programming Guide
32
MG.11.CB.02 - VLT
®
is a registered Danfoss trademark
3