1.
2.
-
-
1.
2.
-
-
1.
2.
-
-
Example
Illustration 40: Instantiation of AXIS_REF_DDS and Setting of Initial Values
6.5.6 Instantiating PSM_REF in Automation Studio™
Procedure
Create 1 instance of function block
PSM_REF
(located in folder
DDS_PSM
) for every Power Supply Module (PSM 510) that
has to be controlled or monitored.
To create a link to the physical PSM 510, link each instance of
PSM_REF
to 1 physical PSM 510. This makes it the logical
representation of 1 physical PSM 510.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
6.5.7 Instantiating DAM_REF in Automation Studio™
Procedure
Create 1 instance of function block
DAM_REF
(located in folder
DDS_DAM
) for every Decentral Access Module (DAM 510)
that has to be controlled or monitored.
To create a link to the physical DAM 510, link each instance of
DAM_REF
to 1 physical DAM 510. This makes it the logical
representation of 1 physical DAM 510.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
6.5.8 Instantiating ACM_REF in Automation Studio™
Procedure
Create 1 instance of function block
ACM_REF
(located in folder
DDS_ACM
) for every Auxiliary Capacitors Module (ACM 510)
that has to be controlled or monitored.
To create a link to the physical ACM 510, link each instance of
ACM_REF
to 1 physical ACM 510. This makes it the logical
representation of 1 physical ACM 510.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
AQ377148425069en-000101
/ 130R1213
72 | Danfoss A/S © 2023.08
Commissioning
VLT® Servo Drive System ISD 511
Operating Guide