![Danfoss VLT Ea4 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/danfoss/vlt-ea4/vlt-ea4_operating-manual_3870291071.webp)
Encoder input accuracy (1–11 kHz)
Maximum error: 0.05% of full scale
1
FC 302 only.
2
Encoder inputs: 32=A and 33=B.
7.7.5 Analog Output
Number of programmable outputs
1
Terminal number
42
Current range at analog output
0/4 to 20 mA
Maximum load GND - analog output less than
500 Ω
Accuracy on analog output
Maximum error: 0.8% of full scale
Resolution of analog output
8 bit
The analog output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
7.7.6 Control Card, RS485 Serial Communication
Terminal number
68 (P, TX+, RX+), 69 (N, TX-, RX-)
Terminal number 61
Common for terminals 68 and 69
The RS485 serial communication circuit is galvanically isolated from the supply voltage (PELV).
7.7.7 Digital Outputs
Programmable digital/pulse outputs
2
Terminal number
(1)
27, 29
Voltage level at digital/frequency output
0–24 V
Maximum output current (sink or source)
40 mA
Maximum load at frequency output
1 kΩ
Maximum capacitive load at frequency output
10 nF
Minimum output frequency at frequency output
0 Hz
Maximum output frequency at frequency output
32 kHz
Accuracy of frequency output
Maximum error: 0.1% of full scale
Resolution of frequency outputs
12 bit
1
Terminals 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
7.7.8 Control Card, 24 V DC Output
Terminal number
12, 13
Output voltage
24 V +1, -3 V
Maximum load
200 mA
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digital
inputs and outputs.
7.7.9 Relay Outputs
Programmable relay outputs
2
Maximum wire cross-section to relay terminals
2.5 mm
2
(12 AWG)
Minimum wire cross-section to relay terminals
0.2 mm
2
(30 AWG)
Length of stripped wire
8 mm (0.3 in)
Relay 01 terminal number
1–3 (break), 1–2 (make)
AQ434333248451en-000101 / 130R1286 | 71
Danfoss A/S © 2023.01