2 Safety

2.1  Safety Symbols

The following symbols are used in this manual:

WARNING

Indicates a potentially hazardous situation that could
result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation that could
result in minor or moderate injury. It can also be used to
alert against unsafe practices.

NOTICE

Indicates important information, including situations that
can result in damage to equipment or property.

2.2  Qualified Personnel

Correct and reliable transport, storage, installation,
operation, and maintenance are required for the trouble-
free and safe operation of the frequency converter. Only
qualified personnel are allowed to install or operate this
equipment.

Qualified personnel are defined as trained staff, who are
authorised to install, commission, and maintain equipment,
systems, and circuits in accordance with pertinent laws and
regulations. Additionally, the qualified personnel must be
familiar with the instructions and safety measures
described in these operating instructions.

2.3  Safety Precautions

WARNING

HIGH VOLTAGE

Frequency converters contain high voltage when
connected to AC mains input, DC supply, or load sharing.
Failure to perform installation, start-up, and maintenance
by qualified personnel can result in death or serious
injury.

Installation, start-up, and maintenance must be
performed by qualified personnel only.

WARNING

UNINTENDED START

When the frequency converter is connected to AC mains,
DC supply, or load sharing, the motor may start at any
time. Unintended start during programming, service, or
repair work can result in death, serious injury, or
property damage. The motor can start with an external
switch, a fieldbus command, an input reference signal
from the LCP or LOP, via remote operation using MCT 10
Set-up Software, or after a cleared fault condition.
To prevent unintended motor start:

Disconnect the frequency converter from the
mains.

Press [Off/Reset] on the LCP before
programming parameters.

The frequency converter, motor, and any driven
equipment must be fully wired and assembled
when the frequency converter is connected to
AC mains, DC supply, or load sharing.

WARNING

DISCHARGE TIME

The frequency converter contains DC-link capacitors that
can remain charged even when the frequency converter
is not powered. Failure to wait the specified time after
power has been removed before performing service or
repair work, can result in death or serious injury.

Stop the motor.

Disconnect the AC mains and remote DC-link
power supplies, including battery back-ups,
UPS, and DC-link connections to other
frequency converters.

Disconnect or lock the PM motor.

Wait for the capacitors to discharge fully before
performing any service or repair work. The
duration of waiting time is specified in the
relevant frequency converter operating
instructions, 

Chapter 2 Safety

.

WARNING

LEAKAGE CURRENT HAZARD

Leakage currents exceed 3.5 mA. Failure to ground the
frequency converter properly can result in death or
serious injury.

Ensure the correct grounding of the equipment
by a certified electrical installer.

Safety

VLT

®

 DeviceNet MCA 104

4

Danfoss A/S © Rev. 03/2015 All rights reserved.

MG33D502

2

2

Содержание VLT DeviceNet MCA 104

Страница 1: ...MAKING MODERN LIVING POSSIBLE Installation Guide VLT DeviceNet MCA 104 VLT Frequency Converter Series FC 102 FC 202 FC 301 FC 302 vlt drives danfoss com...

Страница 2: ......

Страница 3: ...n 6 3 1 Safety Instructions 6 3 2 EMC compliant Installation 6 3 3 Grounding 6 3 4 Cable Routing 6 3 5 Mounting 7 3 6 Setting Address Switches 8 3 7 Electrical Installation 8 3 8 Reassembling Cover 11...

Страница 4: ...tions and manuals are available from Danfoss See www danfoss com BusinessAreas DrivesSo lutions Documentations VLT Technical Documentation htm for listings 1 3 Product Overview 1 3 1 Intended Use This...

Страница 5: ...AV Main actual value MRV Main reference value MSB Most significant bit N A Not applicable ODVA Open deviceNet vendor association OSI Open systems interconnection PC Personal computer PCD Process data...

Страница 6: ...ing the motor may start at any time Unintended start during programming service or repair work can result in death serious injury or property damage The motor can start with an external switch a field...

Страница 7: ...trical work conforms to national and local electrical codes Follow the procedures in this manual CAUTION INTERNAL FAILURE HAZARD An internal failure in the frequency converter can result in serious in...

Страница 8: ...s as short as possible Establish electrical contact between the cable screen and the frequency converter enclosure by using metal cable glands or by using the clamps provided on the equipment Use high...

Страница 9: ...3 3 or with the connector facing down for bottom cable entry see Illustration 3 4 If an MCB option is installed only top cable entry is possible 5 Remove the knock out plate from the new LCP cradle 6...

Страница 10: ...ameter 10 02 MAC ID ensure that all address switches are set to ON When the address is already set using address hardware switches the address value shown in parameter 10 02 MAC ID is read only Illust...

Страница 11: ...tripped cable between the spring loaded metal clamps to establish mechanical fixation and electrical contact between cable screen and ground 130BD877 10 1 2 1 Cable screen 2 EMC bracket Used for top c...

Страница 12: ...us connector on the fieldbus option terminal V CAN_L Drain CAN_H V 3 Prepare the fieldbus cable by stripping a section of the cable insulation Keep the unshielded wire as short as possible For cable s...

Страница 13: ...side the unit see Illustration 3 12 130BC527 10 Illustration 3 12 Wiring for Enclosure Types D E and F 3 8 Reassembling Cover 1 Mount the new front cover and the LCP 2 Attach the sticker with the corr...

Страница 14: ...2 bi colour LEDs on the DeviceNet card indicate the status of DeviceNet communication The lower LED NS indicates the net status The upper LED MS indicates the module status MS Upper left LED NS Lower...

Страница 15: ...itical link failure Red Table 4 2 LED Network Status NS 4 2 2 No Communication with the Frequency Converter When there is no communication with the frequency converter proceed with the following check...

Страница 16: ...lation 8 Electrical interference 6 EMC interference 6 EMC compliant installation 6 Exploded view 7 G Grounding 6 H High voltage 4 I Intended use 2 Items supplied 2 L Leakage current 4 LED 3 LED panel...

Страница 17: ...Index Installation Guide MG33D502 Danfoss A S Rev 03 2015 All rights reserved 15...

Страница 18: ...ts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respec...

Отзывы: