27-66 Terminal X66/13 Digital Input
Option:
Function:
[134]
Pump 5 Interlock
[135]
Pump 6 Interlock
[136]
Pump 7 Interlock
[137]
Pump 8 Interlock
[138]
Pump 9 Interlock
5.1.10 Connections, 27-7*
Parameters for configuring relay connections.
27-70 Relay
27-70 Relay
is an array parameter used to setup the function of
the option relays. Depending on which option is installed only
the available relays will be visible. If Extended Cascade Controller
is installed, relay 10-12 will be visible. If Advanced Cascade
Controller is installed relay 13-20 will be visible. In both cases,
the standard relays (Relay1 and Relay2) will be accessible as well
as the relays in the B-option MCB 105 (if that option is installed
in combination with advanced cascade).
To setup the function of each relay, choose the specific relays
and then choose the function. If the function option: Standard
Relay is choosen, the relay can be used as general purpose relay
and the wanted function can then be setup in parameter group
5-4* Relays
.
Option:
Function:
[0]
Standard Relay
Enable follower
drive X
[1]
Drive 2 Enable
[2]
Drive 3 Enable
[3]
Drive 4 Enable
[4]
Drive 5 Enable
[5]
Drive 6 Enable
[6]
Drive 7 Enable
[7]
Drive 8 Enable
[8]
Pump 1 to Drive 1
[9]
Pump 1 to Drive 2
[10]
Pump 1 to Drive 3
[11]
Pump 1 to Drive 4
[12]
Pump 1 to Drive 5
[13]
Pump 1 to Drive 6
[14]
Pump 1 to Drive 7
[15]
Pump 1 to Drive 8
[16]
Pump 2 to Drive 1
[17]
Pump 2 to Drive 2
[18]
Pump 2 to Drive 3
[19]
Pump 2 to Drive 4
[20]
Pump 2 to Drive 5
[21]
Pump 2 to Drive 6
[22]
Pump 2 to Drive 7
[23]
Pump 2 to Drive 8
[24]
Pump 3 to Drive 1
[25]
Pump 3 to Drive 2
27-70 Relay
27-70 Relay
is an array parameter used to setup the function of
the option relays. Depending on which option is installed only
the available relays will be visible. If Extended Cascade Controller
is installed, relay 10-12 will be visible. If Advanced Cascade
Controller is installed relay 13-20 will be visible. In both cases,
the standard relays (Relay1 and Relay2) will be accessible as well
as the relays in the B-option MCB 105 (if that option is installed
in combination with advanced cascade).
To setup the function of each relay, choose the specific relays
and then choose the function. If the function option: Standard
Relay is choosen, the relay can be used as general purpose relay
and the wanted function can then be setup in parameter group
5-4* Relays
.
Option:
Function:
[26]
Pump 3 to Drive 3
[27]
Pump 3 to Drive 4
[28]
Pump 3 to Drive 5
[29]
Pump 3 to Drive 6
[30]
Pump 3 to Drive 7
[31]
Pump 3 to Drive 8
[32]
Pump 4 to Drive 1
[33]
Pump 4 to Drive 2
[34]
Pump 4 to Drive 3
[35]
Pump 4 to Drive 4
[36]
Pump 4 to Drive 5
[37]
Pump 4 to Drive 6
[38]
Pump 4 to Drive 7
[39]
Pump 4 to Drive 8
[40]
Pump 5 to Drive 1
[41]
Pump 5 to Drive 2
[42]
Pump 5 to Drive 3
[43]
Pump 5 to Drive 4
[44]
Pump 5 to Drive 5
[45]
Pump 5 to Drive 6
[46]
Pump 5 to Drive 7
[47]
Pump 5 to Drive 8
[48]
Pump 6 to Drive 1
[49]
Pump 6 to Drive 2
[50]
Pump 6 to Drive 3
[51]
Pump 6 to Drive 4
[52]
Pump 6 to Drive 5
[53]
Pump 6 to Drive 6
[54]
Pump 6 to Drive 7
[55]
Pump 6 to Drive 8
[56]
Pump 7 to Drive 1
[57]
Pump 7 to Drive 2
[58]
Pump 7 to Drive 3
[59]
Pump 7 to Drive 4
[60]
Pump 7 to Drive 5
[61]
Pump 7 to Drive 6
[62]
Pump 7 to Drive 7
[63]
Pump 7 to Drive 8
[64]
Pump 8 to Drive 1
Parameter Descriptions
VLT
®
AQUA Drive MCO 101/MCO 102
MI38C402 - VLT
®
is a registered Danfoss trademark
35
5
5