Size mm
A
a
B
b
C
D
E
øa
øb
F
øc
S2 - 200-240 V AC
VLT 2803-2815
200
191
75
60
168
7
5
4.5
8
4
4.5
D2 - 200-240 V AC
VLT 2803-2815
200
191
75
60
168
7
5
4.5
8
4
4.5
VLT 2822*
267.5
257
90
70
168
8
6
5.5
11
4.5
5.5
VLT 2840*
267.5
257
140
120
168
8
6
5.5
11
4.5
5.5
PD2 - 200-240 V AC
VLT 2822
267.5
257
140
120
168
8
6
5.5
11
4.5
5.5
VLT 2840
505
490
200
120
244
7.75
7.25
6.5
13
8
6.5
T2 - 200-240 V AC
VLT 2822
267.5
257
90
70
168
8
6
5.5
11
4.5
5.5
VLT 2840
267.5
257
140
120
168
8
6
5.5
11
4.5
5.5
T4 - 380-480 V AC
VLT 2805-2815
200
191
75
60
168
7
5
4.5
8
4
4.5
VLT 2822-2840
267.5
257
90
70
168
8
6
5.5
11
4.5
5.5
VLT 2855-2875
267.5
257
140
120
168
8
6
5.5
11
4.5
5.5
VLT 2880-2882
505
490
200
120
244
7.75
7.25
6.5
13
8
6.5
Table 3.1 Dimensions
Installation Procedures
1.
Drill holes in accordance with the measurements given in
Table 3.1
. Note the difference in unit voltages.
2.
Retighten all 4 screws.
3.
Fit the decoupling plate to the power cables and the ground screw (terminal 95).
3.2 Motor Coils (195N3110) and RFI 1B Filter (195N3103)
Illustration 3.3 Motor Coils (195N3110)
Illustration 3.4 RFI 1B Filter (195N3103)
Mechanical Installation
Quick Guide
MG28M202
Danfoss A/S © Rev. 2014-03-18 All rights reserved.
7