10.6.2 Power Ratings of VACON® 100 INDUSTRIAL, 380–500 V
Table 32: Power Ratings of VACON
®
100 INDUSTRIAL, Mains Voltage 380–500 V, 50–60 Hz, 3~
En-
clo-
sure
size
Drive
type
(1)
Low
Loada-
bility:
Contin-
uous
current
I
L
[A]
(2)
Low
Loada-
bility:
Input
current
I
in
[A]
(2)
Low
Loada-
bility:
10%
over-
load
current
[A]
(2)
High
load-
abili-
ty:
Con-
tinu-
ous
cur-
rent
I
H
[A]
(2)
High
load-
abili-
ty: In-
put
cur-
rent
I
in
[A]
(2)
High
loada-
bility:
50%
over-
load
cur-
rent
[A]
(2)
Loada-
bility:
Max
cur-
rent I
s
2 s
(2)
Motor
shaft
power
(3)
:
10%
over-
load
40°C
[kW]
Motor
shaft
power
(3)
:
50%
over-
load
50°C
[kW]
Motor
shaft
power
(4)
: 10%
over-
load
40°C
[hp]
Mo-
tor
shaft
pow-
er
(4)
:
50%
over-
load
50°C
[hp]
MR4
0003
3.4
3.4
3.7
2.6
2.8
3.9
5.2
1.1
0.75
1.5
1.0
0004
4.8
4.6
5.3
3.4
3.4
5.1
6.8
1.5
1.1
2.0
1.5
0005
5.6
5.4
6.2
4.3
4.2
6.5
8.6
2.2
1.5
3.0
2.0
0008
8.0
8.1
8.8
5.6
6.0
8.4
11.2
3.0
2.2
4.0
3.0
0009
9.6
9.3
10.6
8.0
8.1
12.0
16.0
4.0
3.0
5.0
4.0
0012
12.0
11.3
13.2
9.6
9.3
14.4
19.2
5.5
4.0
7.5
5.0
MR5
0016
16.0
15.4
17.6
12.0
12.4
18.0
24.0
7.5
5.5
10.0
7.5
0023
23.0
21.3
25.3
16.0
15.4
24.0
32.0
11.0
7.5
15.0
10.0
0031
31.0
28.4
34.1
23.0
21.6
34.5
46.0
15.0
11.0
20.0
15.0
MR6
0038
38.0
36.7
41.8
31.0
30.5
46.5
62.0
18.5
15.0
25.0
20.0
0046
46.0
43.6
50.6
38.0
36.7
57.0
76.0
22.0
18.5
30.0
25.0
0061
61.0
58.2
67.1
46.0
45.6
69.0
92.0
30.0
22.0
40.0
30.0
MR7
0072
72.0
67.5
79.2
61.0
58.2
91.5
122.0
37.0
30.0
50.0
40.0
0087
87.0
85.3
95.7
72.0
72.0
108.0
144.0
45.0
37.0
60.0
50.0
0105
105.0
100.6
115.5
87.0
85.3
130.5
174.0
55.0
45.0
75.0
60.0
MR8
0140
140.0
139.4
154.0
105.0
109.0
157.5
210.0
75.0
55.0
100.0
75.0
0170
170.0
166.5
187.0
140.0
139.4
210.0
280.0
90.0
75.0
125.0
100.0
0205
205.0
199.6
225.5
170.0
166.5
255.0
340.0
110.0
90.0
150.0
125.0
MR9A
0261
261.0
258.0
287.1
205.0
204.0
307.5
410.0
132.0
110.0
200.0
150.0
0310
310.0
303.0
341.0
251.0
246.0
376.5
502.0
160.0
132.0
250.0
200.0
MR9B
0386
385.0
385.0
423.5
310.0
311.0
465.0
620.0
200.0
160.0
300.0
250.0
1
The currents in given ambient temperatures are achieved only when the switching frequency is the same or smaller than the factory default
2
See
.
3
400 V
4
480 V
If the process includes a cyclical load, for example if there are lifts or winches, speak to the manufacturer to get the dimensioning
information.
Specifications
Operating Guide | VACON® 100 Wall-mounted Drives
AQ298036140958en-000101 / DPD01711
116 | Danfoss A/S © 2019.05