51
Annex
TFX INSTALLATION AND OPERATION MANUAL
6046279-001 March 2020
Analog IN (reset)
2 analog factory setting inputs
Measurement range: 0 VDC to 78 V
DC
Input resistance: 103 kΩ
Surge-proof up to 53 V
DC
Reverse voltage protection up to -53 V
DC
Tolerance: ± 1 % of measurement range end
value (at 25 °C)
Terminal 30
1 analog input
Measurement range: 0 V
DC
to 78 V
DC
Input resistance: 103 kΩ
Sampling rate: 20 Hz
Surge-proof up to 36 V
DC
Reverse voltage protection up to -36 V
DC
Tolerance: ± 1 % of measurement range end
value (at 25 °C)
Acceleration sensor
Gyro sensor / rate of
rotation sensor
Tolerance: ≤3 % of measurement range end
Temperature sensor
Sampling rate: 20 Hz
9.2.4 Protocols
Table 41: Protocols
Protocols
Layer 2
Yes
CANopen
Yes
J1939, OBDII
Yes
Customer-specific
On request
TCP
Yes
SDO client
Yes
9.2.5 Status indicators
Table 42: Status indicators
Status indicators
All model variants
2 RGB LEDs (ON / STATUS)
9.3 Certification and qualification
The device has been certified and qualified according to the
valid standards and regulations.
For more information on the corresponding approval tests,
please contact the support service. See chapter Service
and support.
INFORMATION
We will send you an overview of national approvals
on request.
Please contact our support service. See chapter Service
and support.
PROEMION GmbH hereby declares that the TFX radio
system complies with the 2014/53/EU directive.
The full text of the conformity declarations is available
here: https://conformity.proemion.com
E1
ECE Regulation No. 10 (version 5)
Approval number: