35
Operation
TFX INSTALLATION AND OPERATION MANUAL
6046279-001 March 2020
The file has the following structure:
> Unix timestamp indicating when the value was read out
(only once per transmission)
> The line starts with a colon (:)
> Object index (e.g. 0x3333)
> Comma (,)
> Sub-Index (e.g. 0x38)
> Comma (,)
> Read-off value in decimal or text form
> Semicolon (;)
> End of line <CR><LF>
If the file is not removed from the server, lines are added
to the existing file when the next instruction to read
is received. The timestamp then provides a distinction
between the read instructions.
Example:
UTC:1430123506
: 0x3333, 0x38, 60;
5.8 Configuration update
Use DANFOSS Configurator to load a configuration update to
the device.
The configuration update can be loaded to the device via
the CAN interface or the Data platform. The device identifies
and automatically loads the new configuration.
For more detailed information on creating a configuration,
see chapter Customizing the demo configuration file.
5.8.1 Data platform
Authorization to perform a configuration update must be
registered on the Data platform. Generally, users with
administrator rights have this authorization.
INFORMATION
If you do not have authorization to perform a configuration
update, contact the service support. See chapter Service
and support.
1. Start the DANFOSS Configurator software.
2. Open the corresponding configuration file (.DOD).
3. Click on T
ARGET
D
EVI CE
> O
B JE CT
D
ICTIONARY
> D
OWNLOA D
>
R
EMOTE
D
OWNLOA D
- A
LL
E
NTRIES
or click on the arrow in
the toolbar next to the symbol
D
OWNLOA D
ALL
E
NTRIES
.
The window R
EMOTE
CONFIGURATION
DOWNLOA D
TO
TARGET
(S )
opens.
4. In the window R
EMOTE
C
ONFIGURATION
D
OWNLOA D
TO
T
ARGET
(S ), click on the S
ELE CT
D
EVI CES
button.
The window S
ELE CT
D
EVI CES
opens.
5. Enter your PROEMION user name and password in
the S
ELE CT
D
EVI CES
window.
6. Click on the L
OGIN
button.
7. Select the device. The device does not have to
be online.
8. Click on the OK button.
NOTICE
Loss of connection due to incorrect parameters.
The online connection may be lost due to incorrect provider
parameters. In most cases, it is not necessary to update the
security variables, so this should be avoided.
•
Before each update of the security variables, check the
provider parameters.
9. In the window R
EMOTE
CONFIGURATION
DOWNLOA D
TO
TARGET
(
S
), click on the S
TART
button.
The following warning appears.
You are warned against downloading untested
configuration files.