8 | © Danfoss | Energy Meters | 2018.01 

VUIGB802

Installation & User Guide 

SonoSelect and SonoSafe

2 pulse input module

Once installed the meter will display the icon for pulse inputs in menu 2 of the display. Accumulated 
volume is only readable by communication. The two pulse inputs can be programmed independently of 
each other.

Pulse value

0.001 m³ to 1 m³ per pulse

Voltage supply

≤ 6.0 V

Source current

≤ 0.1 mA

High level input threshold

≥ 2 V

Low level input threshold

≤ 0.5 V

Pull-up resistor

100 kΩ

Pulse length

≥100 ms

Maximum frequency

≤ 5 Hz

Pulse inputs

According to EN1434-2, section 7.1.5 (Classification of pulse input devices Class IB)

Battery life time

16+1 year

* Suitable for both electronic switch and Reed contact.

2 pulse output module

Once installed the meter will display the icon for wired communication in menu 2 of the display. 

Pulse 1 (energy*)

+ terminal 16, - terminal 17

Pulse 2 (volume*)

+ terminal 18, - terminal 19

Pulse value*

Unit follow the display. Scaling follow least significant digit of the display 

(default setting can be changed via SonoApp)

Pulse timing

Updates every 15 seconds

Polarity reversal:

Not possible, but can withstand -30V, max 27 mA without damage

Pulse length

≥100 ms

Pulse Pause:

≥100 ms

Voltage supply

3-30 V

Source current

≤ 27 mA

“ON” condition

U<2,0 @ 27mA

“OFF” condition

R>=6 MΩ

Maximum frequency

≤ 5 Hz

Pulse outputs

According to EN1434-2, section 8.2.3  

(Classification of pulse output devices Class OB)

Battery life time

16+1 year

Cable length

Max 25 m

Alarms

E32 activates in meter if:

1) Module battery is empty

2) When no. of delayed pulses exceeds 5000 (incorrect scaling)

*Default setting. Can be changed via SonoApp.

Содержание SonoSafe

Страница 1: ...1 09 2017 Danfoss VUIGB802 www heating danfoss com Installation User Guide SonoSelect and SonoSafe Energy Meters...

Страница 2: ...rovided that the product is used in accordance with our instructions MID Directive 2014 32 EU Measuring Instrument Directive Module B D o EN1434 4 2015 Notified Body Force Certification 0200 performed...

Страница 3: ...2 3 Flow sensor installation 5 2 4 Mounting orientation calculator 5 2 5 Mounting of O ring and temperature sensor 6 2 6 Communication Expansion modules 7 2 7 Installation of module cable 10 2 8 Batt...

Страница 4: ...product 2 Installation 2 1 Preparation SonoSelect incorporates a tamper monitoring function If the calculator is opened the meter will set alarm E13 in display Don t open unless for adding communicat...

Страница 5: ...llation Note Heat meters have red temp sensor in supply pipe and all cooling meters have blue temp sensor in supply pipe 2 3 Flow sensor installation Pipe position No limitations but avoid positions w...

Страница 6: ...Mounting pin available as accessory 1 Mount O ring on pin 2 Insert pin with O ring 3 Position O ring 4 Remove pin 5 Moist and insert sensor probe Tighten at torque 12 2 Nm To ensure accuracy and a tig...

Страница 7: ...r and pulse inputs The two pulse inputs can be programmed independently of each other see specification for pulse input module M Bus primary Lithium Thionyl Chloride battery half of AA size M Bus seco...

Страница 8: ...2 pulse output module Once installed the meter will display the icon for wired communication in menu 2 of the display Pulse 1 energy terminal 16 terminal 17 Pulse 2 volume terminal 18 terminal 19 Pul...

Страница 9: ...egram Walk by 2 minutes sending interval Accumulated energy Accumulated volume CurrentTime Hour counter factory Month log 1 last month log Can be changed via SonoApp Terminals and cables Communication...

Страница 10: ...l to enclosure 4 Insert module following guide on PCBA cover Insert cable through hole connect cable and fix to screw terminals matching color and terminal numbers Fix cable s to cable relief Outer ja...

Страница 11: ...n enclosure 3 Disconnect battery connector and remove battery 4 Short circuit battery connectors on PCB using a small flat head screwdriver 5 Connect new battery to PCB 6 Fit battery in enclosure 7 Cl...

Страница 12: ...For SonoSelect Run installation check using Bluetooth dongle 014U1963 and SonoApp service tool 3 2 Supply return configuration Only available for SonoSelect Use Bluetooth dongle 014U1963 and SonoApp s...

Страница 13: ...es as well as the current and historical values are stored in the calculator and can be displayed via the control button 4 1 Menu structure Hours Alarm Energy Volume LOOP 1 Supply temp Display test Al...

Страница 14: ...ulse Return temperature Decimal emphasizer Temperature difference Units field 4 3 Alarms E01 System error E09 Low transducer signal E02 PCB error E10 Transducer error E03 Battery empty less than 1 mon...

Страница 15: ...1 Module PCB 12 Bottom part PC 13 Temperature sensor 6 Disposal Item Material Disposal Battery AA cell Lithium thionyl chloride 620 mg Lithium Approved deposit for lithium batteries PCBA with display...

Страница 16: ...16 Danfoss Energy Meters 2016 09 VUIGB802...

Отзывы: