manualshive.com logo in svg
background image

2 | © Danfoss | Energy Meters | 2018.01 

VUIGB802

Installation & User Guide 

SonoSelect and SonoSafe

 

Date 

Issued by 

Place of issue 

Date 

Approved by 

 

2017.08.08 

 

Nordborg, DK 

Søren Nielsen 

R&D Director, Danfoss Energy Metering 

 

2017.08.08 

 

 

Bjarne Halkjær  

Strategy & portfolio Director 

 

Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into 

any other language, the translator concerned shall be liable for the correctness of the translation 

 

ID No:   014R2903 

Revision No:   10 

Page

 

1 of 1 

 

Danfoss A/S 

DK-6430 Nordborg 

Denmark 

CVR nr.: 20 16 57 15 

 

Telephone: +45 7488 2222 

Fax:               +45 7449 0949 

EU DECLARATION OF CONFORMITY 

Danfoss A/S

 

Danfoss Energy Metering 

declares under our sole responsibility that the  

Product(s): 

Energy Meters 

Type(s): 
 

SonoSelect 10 and SonoSafe 10

 

covered by this declaration is in conformity with the following directive(s), standard(s) or other normative 

document(s), provided that the product is used in accordance with our instructions. 

 

MID Directive 2014/32/EU 

Measuring Instrument Directive  

Module B +D 

 

o

 

EN1434-4:2015 

 

Notified Body: Force Certification, 0200, performed type approval and issued certificate DK-0200-MI004-034 

 

EMC Directive 2014/30/EU 

Electromagnetic Compatibility

1

 

o

 

EN 61000-6-1:2007 

 

o

 

EN 61000-6-3:2007/A1:2011    

 

RoHS Directive 2011/65/EU  

Restriction of Hazardous substances 

o

 

EN 50581:2012 

 

 

RED Directive 2014/53/EU 

Radio Equipment Directive

2

 

o

 

EN 300 220-2 V3.1.1 

 

o

 

EN 301 489-1 V1.9.2:2011-09 

o

 

EN 301 489-3 V1.6.1:2013-06  

o

 

EN 62311:2008 

 

o

 

EN 61010-1:2010  

o

 

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/AC:2011/A2:2013 

Notified Body: Eurofins GmbH, 0681, performed type approval and issued certificate G0M-1608-5835-V01 

 

LVD Directive 2014/35/EU 

Low Voltage Directive

1

 

o

 

EN 62311:2008 

 

o

 

EN 61010-1:2010  

o

 

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/AC:2011/A2:2013 

                                                        

1

 For variants with Radio Module the declaration for EMC & LVD shall be ignored 

2

 For variants without Radio Module the declaration for RED shall be ignored

 

Note:

 To ensure latest version of declaration, please visit danfoss.com.

Содержание SonoSafe

Страница 1: ...1 09 2017 Danfoss VUIGB802 www heating danfoss com Installation User Guide SonoSelect and SonoSafe Energy Meters...

Страница 2: ...rovided that the product is used in accordance with our instructions MID Directive 2014 32 EU Measuring Instrument Directive Module B D o EN1434 4 2015 Notified Body Force Certification 0200 performed...

Страница 3: ...2 3 Flow sensor installation 5 2 4 Mounting orientation calculator 5 2 5 Mounting of O ring and temperature sensor 6 2 6 Communication Expansion modules 7 2 7 Installation of module cable 10 2 8 Batt...

Страница 4: ...product 2 Installation 2 1 Preparation SonoSelect incorporates a tamper monitoring function If the calculator is opened the meter will set alarm E13 in display Don t open unless for adding communicat...

Страница 5: ...llation Note Heat meters have red temp sensor in supply pipe and all cooling meters have blue temp sensor in supply pipe 2 3 Flow sensor installation Pipe position No limitations but avoid positions w...

Страница 6: ...Mounting pin available as accessory 1 Mount O ring on pin 2 Insert pin with O ring 3 Position O ring 4 Remove pin 5 Moist and insert sensor probe Tighten at torque 12 2 Nm To ensure accuracy and a tig...

Страница 7: ...r and pulse inputs The two pulse inputs can be programmed independently of each other see specification for pulse input module M Bus primary Lithium Thionyl Chloride battery half of AA size M Bus seco...

Страница 8: ...2 pulse output module Once installed the meter will display the icon for wired communication in menu 2 of the display Pulse 1 energy terminal 16 terminal 17 Pulse 2 volume terminal 18 terminal 19 Pul...

Страница 9: ...egram Walk by 2 minutes sending interval Accumulated energy Accumulated volume CurrentTime Hour counter factory Month log 1 last month log Can be changed via SonoApp Terminals and cables Communication...

Страница 10: ...l to enclosure 4 Insert module following guide on PCBA cover Insert cable through hole connect cable and fix to screw terminals matching color and terminal numbers Fix cable s to cable relief Outer ja...

Страница 11: ...n enclosure 3 Disconnect battery connector and remove battery 4 Short circuit battery connectors on PCB using a small flat head screwdriver 5 Connect new battery to PCB 6 Fit battery in enclosure 7 Cl...

Страница 12: ...For SonoSelect Run installation check using Bluetooth dongle 014U1963 and SonoApp service tool 3 2 Supply return configuration Only available for SonoSelect Use Bluetooth dongle 014U1963 and SonoApp s...

Страница 13: ...es as well as the current and historical values are stored in the calculator and can be displayed via the control button 4 1 Menu structure Hours Alarm Energy Volume LOOP 1 Supply temp Display test Al...

Страница 14: ...ulse Return temperature Decimal emphasizer Temperature difference Units field 4 3 Alarms E01 System error E09 Low transducer signal E02 PCB error E10 Transducer error E03 Battery empty less than 1 mon...

Страница 15: ...1 Module PCB 12 Bottom part PC 13 Temperature sensor 6 Disposal Item Material Disposal Battery AA cell Lithium thionyl chloride 620 mg Lithium Approved deposit for lithium batteries PCBA with display...

Страница 16: ...16 Danfoss Energy Meters 2016 09 VUIGB802...

Отзывы: