background image

Danfoss Heating

9

GB

3.4  Typical Gravity DHW Pumped HTG with    
 

Spring Return Zone Valve in DHW

Other Danfoss Randall products suitable for use with above circuit:-
AT cylinder thermostat; 
HP28C motorised zone valve with spring return actuator and SPDT 
auxiliary switch.

N L 1 2 3 4 5 6

3 amp fuse 

D.H.W.

HTG

ON

OFF

Mains 
Supply

N

L

Programmer 
Terminals

N

N

N

Boiler

Pump

Room

Stat

ON

OFF

N

S.R.Z.V 

in DHW

Cyl. 
Stat

Содержание SET 3E

Страница 1: ...SET 3E Electronic 24 Hour Programmer for Heating and Hot Water Installation Guide Danfoss Heating MAKING MODERN LIVING POSSIBLE...

Страница 2: ...7400 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material All trademarks in this material are property of the respective companies Danfoss and t...

Страница 3: ...DHW Pumped HTG 7 3 3 Typical Fully Pumped System with Spring Return Zone Valve in Heating 8 3 4 Typical Gravity DHW Pumped HTG with Spring Return Zone Valve in DHW 9 3 5 Typical Fully Pumped System wi...

Страница 4: ...ctrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations 1 Fix the wallplate to the wall or ush mounted box as required The connectio...

Страница 5: ...s into the wallplate Tighten the two xing screws to secure the unit to the wallplate 9 Before setting the programme check the unit and circuit Switch ON the mains supply and press both WATER HEATING r...

Страница 6: ...LLPLATE N L 1 2 3 4 5 6 TIMER OFF COM DHW ON N C COM HTG OFF N O N C Typical wiring diagrams for various types of systems are shown on the following pages Note Whilst every attempt has been made to en...

Страница 7: ...anfoss Heating 7 GB DHW Domestic Hot Water 3 2 Typical Gravity DHW Pumped HTG N L 1 2 3 4 5 6 3 amp fuse D H W HTG ON OFF Mains Supply N L Programmer Terminals N N N Boiler Pump Room Stat ON OFF Links...

Страница 8: ...fuse D H W HTG ON OFF Mains Supply N L Programmer Terminals N Boiler Pump S R Z V in HTG Room Stat ON OFF Cyl Stat N N Links Other Danfoss Randall products suitable for use with above circuit AT cylin...

Страница 9: ...oss Randall products suitable for use with above circuit AT cylinder thermostat HP28C motorised zone valve with spring return actuator and SPDT auxiliary switch N L 1 2 3 4 5 6 3 amp fuse D H W HTG ON...

Страница 10: ...6 3 amp fuse D H W HTG ON OFF Mains Supply N L Programmer Terminals N N 3 port mid pos valve Room Stat ON OFF N Boiler Pump Cyl Stat Links Other Danfoss Randall products suitable for use with above c...

Страница 11: ...l products suitable for use with above circuit AT cylinder thermostat 2 x HP22 or HP28 motorised zone valve with spring return actuator and SPST auxiliary switch N L 1 2 3 4 5 6 3 amp fuse D H W HTG O...

Страница 12: ...Valve in each Service N L 1 2 3 4 5 6 3 amp fuse D H W HTG ON OFF Mains Supply N L Programmer Terminals N N F M Z V in HTG Room Stat ON OFF N Boiler Cyl Stat Links N F M Z V in DHW Other Danfoss Randa...

Страница 13: ...mn headed NOTE The conversion applies only if to determine whether the SET3E GRAVITY or PUMPED is the correct conversion If there is any doubt about the way in which the existing programmer is connect...

Страница 14: ...FOSS RANDALL 4033 7 6 4 1 5 2 3 DANFOSS RANDALL SET5 N L 1 2 3 4 5 6 Pumped Gravity link is set to pumped GLOWWORM MASTERMIND N L 3 1 4 2 Pumped Gravity link is set to pumped HONEYWELL ST7100 N L 8 6...

Страница 15: ...CHWELL LIBRA DHP 2201 1 2 6 7 8 3 4 5 SATCHWELL ET1401 ET1451 1 2 7 6 8 4 3 5 SMITH IND CENTROLLER 90 1 2 5 4 3 6 SMITH IND CENTROLLER 1000 N L 3 1 4 2 Pumped Gravity link is set to pumped SWITCHMASTE...

Страница 16: ...Part No 8633v01s6 1 03 11 Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 0845 1217 400 Fax 0845 1217 515 Email danfossrandall danfoss com Website www danfoss randall co uk...

Отзывы: