background image

NAMRON THERMOSTAT

TOUCH ZIGBEE 16A 

INSTRUCTION MANUAL

Summary of Contents for ZIGBEE 16A

Page 1: ...NAMRON THERMOSTAT TOUCH ZIGBEE 16A INSTRUCTION MANUAL ...

Page 2: ...figured through advance config parameter 10 1 Away 2 Auto 3 Manual 4 Drying 5 Off Standard EN 60730 1 2016 A1 EN IEC 60730 2 9 2019 A1 EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETSI EN300 220 2 V3 2 1 RED 2014 53 EU Certificate ZigBee 3 0 CE RED NTC ...

Page 3: ... small screwdriver Insert the wires to the correct terminals as presented in the wiring diagram above Suggested wire stripping length is 8 10mm Fix the thermostat into the connection box by tightening the screws Make sure that the thermostat is fixed without deformation Suggested torque is 0 2 0 4Nm 2 0 4 1kgf cm NTC L L N N L N Floor temp sensor 4512737 1 Wiring diagram 2 Mounting a b c ...

Page 4: ...alternatively for 3 seconds and last displayed mode will be selected or just short press F button to select a desired mode when the modes icon displayed alternatively Press and hold button on Home interface for over 3 seconds to select Away mode directly then Press and hold button for 3 seconds to quit Away mode 1 Away Mode Schedule Time Setting Select TIME DATE on Home Interface to enter into TIM...

Page 5: ...cording to current set temperature The temperature can be set by move up and move down button on the Home interface or configured by Zigbee gateway 4 Dry Mode Schedule Once the device is powered on and stable referring to the room temperature sensor if the temperature decreases to the threshold of this setting the window open mark will be enabled the relay will be forced to turn off to save energy...

Page 6: ...te Hysterersis 0x100A of Thermostat Cluster 0x0201 Note This hysterersis only valid when the control type is single sensor please refer to the part Control Type Or can be configured through the attribute AlarmAirTempOverValue 0x2001 of Thermostat Cluster 0x0201 when this value is set as 0 this function is disabled Monitor Set Over current Alarm If room temperature or floor temperature is over the ...

Page 7: ...e is 5 5 C stepping is 0 5 C This value can also be configured through the attribute Local TemperatureCalibration 0x0010 of Thermostat Cluster 0x0201 and through the proprietary attribute FloorSensorCalibration 0x1005 of Thermostat Cluster 0x0201 Other Set Temperature Compensation 0 by default last status by default Home Temp by default Device state after reset power of the device If set as last s...

Page 8: ... F F Configure Device Operation Mode through Zigbee 5 1 Application Endpoint 0 ZigBee Device Object Application profile Id 0x0000 Application device Id 0x0000 Supports all mandatory clusters Since Zigbee does not have away mode the attribute Occupancy occupied or unoccupied of Thermostat 0x0201 and attribute Occupancy of received OccupancySensing 0x0406 are required to judge whether it is away mod...

Page 9: ...where each scene consists of a pre set on off state value You may either store the current values as a scene or provide scene settings when adding a scene or delete scenes 0x0201 server Thermostat 0x0702 server Simple Meter 0x0b04 server Electrical Measurement Measuring power voltage current 0x0002 INT8U read only StackVersion 0x0003 INT8U read only HWVersion Hardware version 1 0x0004 string read ...

Page 10: ...stored on the device Command supported Command Description 0x00 Add Scene Adds a scene with or without a scene field set 0x01 Returns the scene field set name and transition times for a scene View Scene 0x02 Removes a scene from the scene table Remove Scene 0x03 Removes all scenes that belong to a particular group Remove All Scenes 0x0003 bool read only SceneValid If true the scene identified by C...

Page 11: ...s identifying 0x0002 bitmap8 read only When this flag is set as 1 it means occupied OccupiedHeatingSetpoint will be used otherwise UnoccupiedHeatingSetpoint will be used Occupancy 0x0010 Int8S reportable LocalTemperatureCalibration Room temperature calibration range is 30 30 the maximum resolution this format allows 0 1 C Default value 0 0x0011 int16S reportable OccupiedCoolingSetpoint This system...

Page 12: ...Default Value 2 NTC 15K 25 0x1224 0x1003 ENUM8 reportable ControlType Value 0 Room sensor Default Value 1 floor sensor Value 2 Room floor sensor The referring sensor for heat control 0x1224 0x1007 ENUM8 reportable Value 3 Away mode Value 0 OFF Value 2 Auto mode schedule default ModeAfterDry The mode after Dry Mode Value 1 Manual mode 0x1224 0x1008 ENUM8 reportable Value 1 Floor Temp Value 0 Room T...

Page 13: ...t of metering data this is always kWh 0x00 0x0301 Int24U read only Multiplier 0x0302 Int24U read only Divisor 0x0303 map8 read only The decimal point on the left and right sides of the data this is always 0x00 SummationFormatting 0x2002 ENUM8 reportable Value 1 away Value 0 not away default Away Mode Set 0x1224 0x100B ENUM8 reportable 0 disable Display Auto Off function DisplayAutoOffEnable 1 enab...

Page 14: ...oprietary Attributes Attribute 0x0000 Type Int8u reportable Manufacturer code 0x1224 Description OverCurrent Over current value set by the user range is 0 10 16 ACCurrentOverload will change spontaneously if this value is modified 5 2 7 Alarm 0x0009 Server The Alarm Server cluster can generate the following commands Please set a valid value for ACAlarmsMask of Electrical Measurement The Time clust...

Page 15: ...r Identify 0x0019 Client OTA Upgrade Pull oriented firmware upgrade Searches the network for mating servers and allows the server to control all stages of the upgrade process including which image to download when to download at what rate and when to install the downloaded image Ota complies to standard Zigbee protocol 5 2 10 Thermostat User Interface Configuration 0x0204 Server Attributes support...

Page 16: ...Namron AS Nedre kalbakkvei 88B 1081 Oslo Norway post namron com ...