Control current
Voltage
Min. current to stroke pump
Pin connections
12 V
750 mA
any order
24 V
380 mA
DEUTSCH connector, 2-pin
1
2
P003 480
Connector ordering data
Description
Quantity
Ordering data
Mating connector
1
DEUTSCH DT06-2S
Wedge lock
1
DEUTSCH W2S
Socket contact (16 and 18 AWG)
2
DEUTSCH 0462-201-16141
Danfoss mating connector kit
1
K29657
Solenoid data
Voltage
12 V
24 V
Minimum supply voltage
9.5 V
DC
19 V
DC
Maximum supply voltage (continuous)
14.6 V
DC
29 V
DC
Maximum current
1050 mA
500 mA
Nominal coil resistance @ 20 °C [70 °F]
8.4 Ω
34.5 Ω
PWM Range
70-200 Hz
PWM Frequency (preferred)
*
100 Hz
IP Rating (IEC 60 529) + DIN 40 050, part 9
IP 67 / IP 69K (part 9 with mating connector)
Bi-directional diode cut off voltage
28 V
DC
53 V
DC
*
PWM signal required for optimum control performance.
Pump output flow direction vs. control signal
Shaft rotation
CW
CCW
Coil energized
*
C1
C2
C1
C2
Port A
in
out
out
in
Port B
out
in
in
out
Servo port pressurized
M5
M4
M5
M4
*
For coil location see Installation Drawings.
Control Response
H1controls are available with optional control passage orifices to assist in matching the rate of swash-
plate response to the application requirements.
The time required for the pump output flow to change from zero to full flow (acceleration) or full flow to
zero (deceleration) is a net function of spool porting, orifices, and charge pressure.
Service Manual
MP1
Operation
26 |
©
Danfoss | April 2019
AX00000244en-000201