MP1 loop flushing removal (28/32)
1. Using an 11/16 inch wrench, remove plug (L150).
2. Using a ¼ inch internal hex, remove plug (G115).
3. Remove and discard O-ring (9Q50A).
4. Remove loop flushing spool (L100)
5. Using a 3 mm internal hex, remove orifice (L200).
MP1 loop flushing torque information
Loop flushing removal
L150
L100
L200
G115
P109066
9Q50A
Identification and torque
Item
Wrench size
Torque
Plug (L150)
11/16 inch
45 N•m [33 lbf•ft]
Orifice (L200)
3 mm internal hex
2.5 N•m [1.8 lbf•ft]
Plug (G115)
1/4 inch
40 N•m [30 lbf•ft]
Service Manual
MP1
Minor repair
©
Danfoss | April 2019
AX00000244en-000201 | 61