MP1 EDC control identification
D150
D250
D300 (2x)
F00B
F00A
Item
Description
Wrench size
Torque
D150
Control gasket
-
-
D300
Dowel pins
-
-
D250
Cap screw
5 mm internal hex
13 Nm [9.8 lbf•ft]
F00B
Servo orifice
3 mm internal hex
7.9 Nm [5.8 lbf•ft]
F00A
Servo orifice
3 mm internal hex
7.9 Nm [5.8 lbf•ft]
Controls inspection
Inspect the machined surfaces on the control and top of the pump. If you find any nicks or scratches,
replace the component.
MP1 EDC control assembly
Ensure you install dowel pins (D300) in the housing before installing the control.
1. Install a new gasket (D150).
2. Install dowel pins (D300) in the housing.
W
Warning
If the feedback pin comes off during operation, the pump will lose control and cause a potentially
hazardous situation. Ensure feedback pin is properly torqued before continuing with reassembly.
Service Manual
MP1
Minor repair
©
Danfoss | April 2019
AX00000244en-000201 | 53