User manual
iSave 21
27
180R9221 / 521B1174 / DKCFN.PS.003.A1.02
8.1 Safety regulations
The operator ensures that all maintenance, inspection and installation work is performed
by authorised, qualified specialist personnel who are thoroughly familiar with the manual.
Before intervening in the iSave/system;
• The power must be shut off and the starting device be locked.
• The pressure in the High Pressure lines must be drained to the Low Pressure side.
• The Water in all connected pipes must be drained.
Always use suitable safety and lifting equipment when handling the iSave, and follow the
instructions in chapter 4.3
• When saftey equipment has been adjusted make sure that proper re-adjustment has
been made before start-up.
• When the system is re-started after service and maintenance follow the instructions in
chapter 7 and in “Start and stop procedures” in appendix. 10.1
8.2 Support
Danfoss A/S offers commissioning and service at the system manufacturer’s location. Rate
quotes are offered upon request.
8.3 Maintenance schedule
The schedule of preventive maintenance below will help ensure that the iSave provides
years of trouble-free performance.
One day after commissioning:
1. Re-check bolts in the foundation and the baseplate of the iSave and tighten the bolts to
specified torque if necessary.
2. Visually inspect all pipe connections / couplings for external leakage.
3. Re-check bolts in all pipe connections / couplings and tighten the bolts to specified
torque if necessary.
4. Replace filters if necessary
5. Clean the filter housing and reinstall filters. Make sure no debris enters the system.
Three months after commissioning:
1. Re-check bolts in the foundation and the baseplate of the iSave and tighten the bolts to
specified torque if necessary.
2. Re-check alignment of iSave baseplate and iSave.
3. Visually inspect all pipe connections / couplings for external leakage.
4. Re-check bolts in all pipe connections / couplings and tighten the bolts to specified
torque if necessary.
5. Replace filters if necessary.
6. Clean the filter elements and install the new filters. Make sure no debris enters the
system.
7. Audibly inspect the iSave assembly. If there is irregular sounds or vibrations inspect the
internals parts of the iSave and replace if necessary.
8 Service/Maintenance
Содержание iSave 21
Страница 5: ...User manual iSave 21 5 180R9221 521B1174 DKCFN PS 003 A1 02 1 CE Declaration of conformity...
Страница 32: ...User manual iSave 21 32 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 38: ...User manual iSave 21 38 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 43: ...User manual iSave 21 43 180R9221 521B1174 DKCFN PS 003 A1 02 10 3 Data sheet...
Страница 44: ...User manual iSave 21 44 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 45: ...www iSave danfoss com Data sheet Energy Recovery Device iSave 21 40 MAKING MODERN LIVING POSSIBLE...
Страница 58: ...User manual iSave 21 58 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 59: ...User manual iSave 21 59 180R9221 521B1174 DKCFN PS 003 A1 02 10 4 iSave part list...
Страница 60: ...User manual iSave 21 60 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 61: ...isave danfoss com iSave 21 Parts list 180R9209 DKCFN PC 003 A2 02 Parts list...
Страница 66: ...Parts list iSave 21 Parts list 6 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Vane pump...
Страница 67: ...Parts list iSave 21 Parts list 7 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Pressure Exchanger...
Страница 68: ...Parts list iSave 21 Parts list 8 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave...
Страница 69: ...Parts list iSave 21 Parts list 9 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave on base plate...
Страница 70: ...User manual iSave 21 70 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 71: ...User manual iSave 21 71 180R9221 521B1174 DKCFN PS 003 A1 02 10 5 iSave overload protection...
Страница 72: ...User manual iSave 21 72 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 73: ...isave danfoss com Overload protection iSave 21 180R9222 521B1175 DKCFN PI 003 L1 02 Instruction...
Страница 80: ...User manual iSave 21 80 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 81: ...User manual iSave 21 81 180R9221 521B1174 DKCFN PS 003 A1 02 10 6 Hose assembly and installation...
Страница 82: ...User manual iSave 21 82 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 85: ...User manual iSave 21 85 180R9221 521B1174 DKCFN PS 003 A1 02 10 7 Service instructions assembly and disassembly...
Страница 86: ...User manual iSave 21 86 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 87: ...isave danfoss com Assembly and disassembly iSave 21 180R9219 521B1171 DKCFN PI 003 K1 02 Service instruction...
Страница 100: ...Service instruction iSave 21 14 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view Vane pump...
Страница 101: ...Service instruction iSave 21 15 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view Pressure Exchanger...
Страница 102: ...Service instruction iSave 21 16 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view iSave...
Страница 103: ...User manual iSave 21 103 180R9221 521B1174 DKCFN PS 003 A1 02 10 8 Operating and maintenance instruction electric motor...
Страница 104: ...User manual iSave 21 104 180R9221 521B1174 DKCFN PS 003 A1 02...