5.11 Flushing
RO membranes require periodic flushing to limit biological fouling.
There are two types of flushing: feed water (Seawater) flush and fresh water (Permeate)
flush.
Regardless of the flush water used, the water must be pre-filtered to the level described in
chapter 5.8. All parts of the iSave must be flushed, i.e. LP- and HP flow channels.
Feed water flushing is part of a normal shutdown sequence. After the HP pump has been
stopped, the permeate and concentrate production will continue until the high-pressure
drops below the osmotic pressure. Both the iSave and the LP seawater feed pump must run
until the conductivity measured at point (7) and (3) are satisfactory. See also P&ID in chapter
5.16.
Fresh water flushing is performed before every extended shutdown of the RO plant.
Permeate is simultaneously fed into the iSave at LP in (2), and either to the HP pump inlet
(1) or through some other injection point such as the CIP connections or full flow cleaning
connection. See also P&ID in chapter 5.16. Permeate may be produced during this flushing
process.
Special attention should be given to the pressure in the HP line (7) as the iSave may start to
cavitate when it runs at high speed and the pressure in the HP line (7) drops below 3 bars.
This can be avoided by reducing the speed of the iSave to about 750 rpm and keeping the
pressure in the HP line at the minimum of 1 bar. At this low pressure the iSave may only run
for a maximum of 10 minutes.
Failing to flush the iSave with fresh water before extended shutdowns may result in ex-
tensive biological growth and cause corrosion in the iSave and other equipment in the RO
system.
5.12 CIP or membrane cleaning
The purpose of membrane cleaning is to reduce scaling and fouling in the membranes. For
optimal performance specific chemicals are required, depending on the cause of the pollu-
tion. After chemical treatment the system must be flushed with fresh water.
The flush water coming out of the membranes may consist of a large amount of suspend-
ed inorganic particles. It is important to assure that these particles are not lead into the
iSave.
It is essential that the water used for the final pre-flush is pre-filtered to a level described
in chapter 5.8.
The iSave should not be exposed to chemicals that will damage the RO membranes
Also see instruction “Membrane cleaning of RO system with iSave unit” in appendix 10.2.
5.13 High pressure remains after shutdown
The HP line of the RO system equipped with an iSave can remain pressurised for a long time
after shutdown. Pressure decreases as water slowly leaks through the iSave. If more rapid
system depressurisation is required, the system should be bled through a suitable valve on
the HP concentrate line.
Always check the pressure in the high-pressure lines before making service in the HP lines
or pressurised equipment.
NB!
Содержание iSave 21
Страница 5: ...User manual iSave 21 5 180R9221 521B1174 DKCFN PS 003 A1 02 1 CE Declaration of conformity...
Страница 32: ...User manual iSave 21 32 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 38: ...User manual iSave 21 38 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 43: ...User manual iSave 21 43 180R9221 521B1174 DKCFN PS 003 A1 02 10 3 Data sheet...
Страница 44: ...User manual iSave 21 44 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 45: ...www iSave danfoss com Data sheet Energy Recovery Device iSave 21 40 MAKING MODERN LIVING POSSIBLE...
Страница 58: ...User manual iSave 21 58 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 59: ...User manual iSave 21 59 180R9221 521B1174 DKCFN PS 003 A1 02 10 4 iSave part list...
Страница 60: ...User manual iSave 21 60 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 61: ...isave danfoss com iSave 21 Parts list 180R9209 DKCFN PC 003 A2 02 Parts list...
Страница 66: ...Parts list iSave 21 Parts list 6 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Vane pump...
Страница 67: ...Parts list iSave 21 Parts list 7 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Pressure Exchanger...
Страница 68: ...Parts list iSave 21 Parts list 8 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave...
Страница 69: ...Parts list iSave 21 Parts list 9 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave on base plate...
Страница 70: ...User manual iSave 21 70 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 71: ...User manual iSave 21 71 180R9221 521B1174 DKCFN PS 003 A1 02 10 5 iSave overload protection...
Страница 72: ...User manual iSave 21 72 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 73: ...isave danfoss com Overload protection iSave 21 180R9222 521B1175 DKCFN PI 003 L1 02 Instruction...
Страница 80: ...User manual iSave 21 80 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 81: ...User manual iSave 21 81 180R9221 521B1174 DKCFN PS 003 A1 02 10 6 Hose assembly and installation...
Страница 82: ...User manual iSave 21 82 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 85: ...User manual iSave 21 85 180R9221 521B1174 DKCFN PS 003 A1 02 10 7 Service instructions assembly and disassembly...
Страница 86: ...User manual iSave 21 86 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 87: ...isave danfoss com Assembly and disassembly iSave 21 180R9219 521B1171 DKCFN PI 003 K1 02 Service instruction...
Страница 100: ...Service instruction iSave 21 14 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view Vane pump...
Страница 101: ...Service instruction iSave 21 15 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view Pressure Exchanger...
Страница 102: ...Service instruction iSave 21 16 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view iSave...
Страница 103: ...User manual iSave 21 103 180R9221 521B1174 DKCFN PS 003 A1 02 10 8 Operating and maintenance instruction electric motor...
Страница 104: ...User manual iSave 21 104 180R9221 521B1174 DKCFN PS 003 A1 02...