User manual
iSave 21
20
180R9221 / 521B1174 / DKCFN.PS.003.A1.02
5.14 Over-pressurisation caused by low pressure isolation
If the low-pressure side of the iSave is blocked and the iSave is exposed to high-pressure,
there is a risk that the iSave or the LP piping could be damaged by over-pressurisation.
To prevent such over-pressurisation, appropriate relief valves should be used and proce-
dures should be implemented to assure that the HP of the iSave is depressurised prior to
the isolation of the LP side.
5.15 Over-pressurisation caused by the high pressure pump.
The HP pump may be able to generate a pressure higher than the maximum allowable
pressure for the iSave or the system – particularly if the HP pump is a positive displacement
pump, the pump will be able to generate extremely high levels of pressure.
To prevent such over-pressurisation, appropriate relief valves should be used and pro-
cedures should be implemented to assure that the HP of the iSave is protected against
excess pressure.
Содержание iSave 21
Страница 5: ...User manual iSave 21 5 180R9221 521B1174 DKCFN PS 003 A1 02 1 CE Declaration of conformity...
Страница 32: ...User manual iSave 21 32 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 38: ...User manual iSave 21 38 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 43: ...User manual iSave 21 43 180R9221 521B1174 DKCFN PS 003 A1 02 10 3 Data sheet...
Страница 44: ...User manual iSave 21 44 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 45: ...www iSave danfoss com Data sheet Energy Recovery Device iSave 21 40 MAKING MODERN LIVING POSSIBLE...
Страница 58: ...User manual iSave 21 58 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 59: ...User manual iSave 21 59 180R9221 521B1174 DKCFN PS 003 A1 02 10 4 iSave part list...
Страница 60: ...User manual iSave 21 60 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 61: ...isave danfoss com iSave 21 Parts list 180R9209 DKCFN PC 003 A2 02 Parts list...
Страница 66: ...Parts list iSave 21 Parts list 6 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Vane pump...
Страница 67: ...Parts list iSave 21 Parts list 7 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view Pressure Exchanger...
Страница 68: ...Parts list iSave 21 Parts list 8 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave...
Страница 69: ...Parts list iSave 21 Parts list 9 180R9209 DKCFN PC 003 A2 02 03 2011 Exploded view iSave on base plate...
Страница 70: ...User manual iSave 21 70 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 71: ...User manual iSave 21 71 180R9221 521B1174 DKCFN PS 003 A1 02 10 5 iSave overload protection...
Страница 72: ...User manual iSave 21 72 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 73: ...isave danfoss com Overload protection iSave 21 180R9222 521B1175 DKCFN PI 003 L1 02 Instruction...
Страница 80: ...User manual iSave 21 80 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 81: ...User manual iSave 21 81 180R9221 521B1174 DKCFN PS 003 A1 02 10 6 Hose assembly and installation...
Страница 82: ...User manual iSave 21 82 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 85: ...User manual iSave 21 85 180R9221 521B1174 DKCFN PS 003 A1 02 10 7 Service instructions assembly and disassembly...
Страница 86: ...User manual iSave 21 86 180R9221 521B1174 DKCFN PS 003 A1 02...
Страница 87: ...isave danfoss com Assembly and disassembly iSave 21 180R9219 521B1171 DKCFN PI 003 K1 02 Service instruction...
Страница 100: ...Service instruction iSave 21 14 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view Vane pump...
Страница 101: ...Service instruction iSave 21 15 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view Pressure Exchanger...
Страница 102: ...Service instruction iSave 21 16 180R9219 521B1171 DKCFN PI 003 K1 02 01 2011 Exploded view iSave...
Страница 103: ...User manual iSave 21 103 180R9221 521B1174 DKCFN PS 003 A1 02 10 8 Operating and maintenance instruction electric motor...
Страница 104: ...User manual iSave 21 104 180R9221 521B1174 DKCFN PS 003 A1 02...