HLP-C

+    

Inverters

I.Introduction 

Thank you for purchasing and using the general-purpose inverter 

of HLP- C

+

 Series of multi-functions and high performance.

The inverter of HLP- C

+

 Series has been developed on basis 

of HLP-A Series keeping the main functions of HLP-A Series 

and with additional functions on request of customers as well 

as smaller size. So the inverter of HLP- C

+

 Series features more 

compact and more powerful functions.

Please read carefully the operation manual before put the 

inverter to use so as to correctly install and operate the inverter, 

give full play to its functions and ensure the safety. Please keep 

the operation manual handy for future reference, maintenance, 

inspection and repair.

Due to the inverter of a kind of electrical and electronic product 

it must be installed, tested and adjusted with parameters by 

specialized engineering persons of motor. The marks of               

               and other simbols in the manual remind you of the 

safety and prevention caustions during the transportation, 

installation,  running  and  inspection.  Please  follow  these 

instructions to make sure the safe use of the inverter. In case of 

any doubt please contact our local agent for consultation. Our 

professional persons are willing and ready to serve you.

The manual is subject to change without notice.

Danger

Caution

 

Danger

  indicates wrong use may kill or injure people.

Caution

  indicates wrong use may damage the inverter 

                or mechanical system.

 Danger

● Be sure to turn off the input power supply before wiring.

● Do not touch any internal ecectrical circuit or component 

when the charging lamp is still on after the AC power supply 

is disconnected, which means the inverter still has high 

voltage inside and it is very dangerous.

Содержание Holip HLP-C+ Series

Страница 1: ......

Страница 2: ......

Страница 3: ...ge and Installation 10 1 Storage 10 2 Installation Locationand Environment 10 3 Installation Space and Direction 10 Wiring 12 1 Main Circuit Schematic Diagram 12 2 Terminals Description 13 3 Basic Con...

Страница 4: ...ance 80 2 Periodical Inspection and Maintenance items 80 3 Fault indication and troubleshooting 81 4 Faults and Analysis 85 Selection of Peripheral Devices and Disposition 88 1 Options 88 2 Dispositio...

Страница 5: ...electronic product it must be installed tested and adjusted with parameters by specialized engineering persons of motor The marks of and other simbols in the manual remind you of the safety and preve...

Страница 6: ...re subject to the effect and damage of static electricity Donn t touch the main circuit boards Installation testing and maintenance must be performed by qualified professional personnel The inverter s...

Страница 7: ...means 1 5KW Series No Trade Mark Check if there is something wrong on the inner parts wiring and circuit board Check if each terminal is tightly locked andif there is any foreign article insie the inv...

Страница 8: ...inals never mixed with U V W terminals Be sure that the wiring of the main circuit is correct Otherwise it will cause damages of the inverter when the power is delivered to it Do not carry the front c...

Страница 9: ...e inverter in a space with explosive gas to avoid the risk of explosion If the inverter is used at or above 1000m above seal level the cooling efficiency will be worse so please run it by changing dow...

Страница 10: ...s connected to the front end of input of the inverter to control its starting and stopping Generally it is required to control it through FOR or REV terminals Special attention should be paid to its u...

Страница 11: ...speed to higher speed Do not check the signals on circuit boards while the inverter is running to avoid danger Be careful when changing the inverter settings The inverter has been adjusted and set be...

Страница 12: ...PWM Input Power 400V class 345 440V 230V class 170 230V Range 0 1 600 0Hz Acuracy Digital 0 01 10 40 Analogue 0 1 25 10 Setting Resolution Digital 0 1Hz Analogue 1 of Max Operating Frequency Output Re...

Страница 13: ...earch PLC traverse function drawing control auto energy savings carrier adjustable by max 16KHz etc 4 Ddigits Display Status Lamp Display frequency current revolution voltage counter temperature press...

Страница 14: ...electrolytic capacity If it needs to be stored for long time be sure to power it one time within a yearand the power on time should be at least above five hours When powered In input the voltage must...

Страница 15: ...d under the inverter bottom base and install again If the inverter is installed on a loose surface stress may cause damage in main circuit so as to damage the inverter The inverter should be installed...

Страница 16: ...nterrupter Use one of anti high harmonic Magnetic contactor Note Do not use the magnetic contactor as the power supply on off button for the inverter AC reactor It is recommended to install a AC react...

Страница 17: ...h single three phase single phase connected to any two phases U V W Output terminals to motor P P r External braking resistor terminals E Ground terminals the third kind of grounding for 230V and spec...

Страница 18: ...e terminals must be connected correctly as the following wiring circuit diagrams Symbol Function Description Factory setting 10 Power supply for analog freqency 10V VI A n a l o g f r e q u e n c y re...

Страница 19: ...and ground the shield layer or two ends of wire tube Be sure to install a No Fuse Breaker NFB between the power supply and the input terminals R S T If using ground fault circuit interrupter please ch...

Страница 20: ...lease change it to a special AC motor for the inverter or add a reactor on the side of the inverter Please lower the carrier frequency if there is longer distance betweent the inerter and the motor Be...

Отзывы: