HLP-C
+
Inverters
Torgue Control
Torque increase settable by max. 10.0%.
The starting torque can reach 150% at
1.0Hz.
Multi-function
input terminals
6 multi-input terminals for 8–speed steps
control, program operation, switch of
4-steps Accel/Decel, UP/DOWN function,
counter, external emergency stop and other
functions.
Multi-function
Onput terminals
2 multi-function output terminals for the
displaying and warning of running, zero
speed, counter, external fault, program
operation and other information.
Other Functions
AVR (auto voltage regulation), Deceleration
stop or self-stop, DC brake, auto reset
and restart, speed search, PLC, traverse
function, drawing control, auto energy-
savings, carrier adjustable by max. 16KHz,
etc.
4-Ddigits Display &
Status Lamp
Display frequency, current, revolution,
voltage, counter, temperature, pressure,
forward or reserve running, and fault, etc.
Communication Control
RS485
Operation Temperature
-10~40
℃
Humidity
0~95% Relative Humidity
(
without dew
)
Viobration
Below 0.5G
Over Voltage
230V class
:
DC Voltage
>
400V400V class
:
DC Voltage
>
800V
Low Voltage
230V class
:
DC Voltage
<
200V400V
class
:
DC Voltage
<
400V
Instant Stop
and Restart
Restarted by speed search after
instantaneous stop.
Stall Prevention
Anti-stall in Acc/Dec Run
Output Eend
Shorts
Electronic circuit protecting
Other Functions
Fin over-heat protection, restriction of reverse
running, fault reset, parameter lock, etc.
G
en
er
al C
on
tr
ol
Pr
ot
ec
tio
n F
un
ct
io
ns