IV.Storage & Installation

⑴ Storage

The inverter must be kept in its original package box before 

installation. Pay attention to the followings when keeping it in 

storage if the inverter is not used for the time being:

● It must be stored in a dry place without rubbish or dust.

● The suitable temperature for storage is between -20

 and 

+65

.

● The relative humidity required is 0-95%, no condensation.

● There is no corrosive gas or liquid in the storage ambience..

● It’s better to lay the inverter on a rack and keep it in a proper 

ipackage.

● It is better not to store the inverter for long time. Long 

time storage of the inverter will lead to the deterioration of 

electrolytic capacity. If it needs to be stored for long time be 

sure to power it one time within a yearand the power on time 

should be at least above five hours. When powered In input 

the voltage must be increased slowly with a voltage regulator 

to the rated voltage value.

⑵ Installation Locationand Environment

Attention: The ambient conditions of the inverter will affect its 

service life.

● Ambient operating temperature -10

 to 40

 with good 

ventilation. 

● No water drop and low moisture.

● Free from direct sunshine, high temperature and heavy dust 

fall.

● Free from corrosive gas or liquid.

● Less dust, oil gas and metallic particles

● Free from vibration and easy for service and inspection.

● Free from the inteference of electromagnetic noise.

⑶ Installation Space and Direction 

● There must be enough space left around the inverter for easy 

maintenance and cooling. See Diagram 1.

Содержание Holip HLP-C+ Series

Страница 1: ......

Страница 2: ......

Страница 3: ...ge and Installation 10 1 Storage 10 2 Installation Locationand Environment 10 3 Installation Space and Direction 10 Wiring 12 1 Main Circuit Schematic Diagram 12 2 Terminals Description 13 3 Basic Con...

Страница 4: ...ance 80 2 Periodical Inspection and Maintenance items 80 3 Fault indication and troubleshooting 81 4 Faults and Analysis 85 Selection of Peripheral Devices and Disposition 88 1 Options 88 2 Dispositio...

Страница 5: ...electronic product it must be installed tested and adjusted with parameters by specialized engineering persons of motor The marks of and other simbols in the manual remind you of the safety and preve...

Страница 6: ...re subject to the effect and damage of static electricity Donn t touch the main circuit boards Installation testing and maintenance must be performed by qualified professional personnel The inverter s...

Страница 7: ...means 1 5KW Series No Trade Mark Check if there is something wrong on the inner parts wiring and circuit board Check if each terminal is tightly locked andif there is any foreign article insie the inv...

Страница 8: ...inals never mixed with U V W terminals Be sure that the wiring of the main circuit is correct Otherwise it will cause damages of the inverter when the power is delivered to it Do not carry the front c...

Страница 9: ...e inverter in a space with explosive gas to avoid the risk of explosion If the inverter is used at or above 1000m above seal level the cooling efficiency will be worse so please run it by changing dow...

Страница 10: ...s connected to the front end of input of the inverter to control its starting and stopping Generally it is required to control it through FOR or REV terminals Special attention should be paid to its u...

Страница 11: ...speed to higher speed Do not check the signals on circuit boards while the inverter is running to avoid danger Be careful when changing the inverter settings The inverter has been adjusted and set be...

Страница 12: ...PWM Input Power 400V class 345 440V 230V class 170 230V Range 0 1 600 0Hz Acuracy Digital 0 01 10 40 Analogue 0 1 25 10 Setting Resolution Digital 0 1Hz Analogue 1 of Max Operating Frequency Output Re...

Страница 13: ...earch PLC traverse function drawing control auto energy savings carrier adjustable by max 16KHz etc 4 Ddigits Display Status Lamp Display frequency current revolution voltage counter temperature press...

Страница 14: ...electrolytic capacity If it needs to be stored for long time be sure to power it one time within a yearand the power on time should be at least above five hours When powered In input the voltage must...

Страница 15: ...d under the inverter bottom base and install again If the inverter is installed on a loose surface stress may cause damage in main circuit so as to damage the inverter The inverter should be installed...

Страница 16: ...nterrupter Use one of anti high harmonic Magnetic contactor Note Do not use the magnetic contactor as the power supply on off button for the inverter AC reactor It is recommended to install a AC react...

Страница 17: ...h single three phase single phase connected to any two phases U V W Output terminals to motor P P r External braking resistor terminals E Ground terminals the third kind of grounding for 230V and spec...

Страница 18: ...e terminals must be connected correctly as the following wiring circuit diagrams Symbol Function Description Factory setting 10 Power supply for analog freqency 10V VI A n a l o g f r e q u e n c y re...

Страница 19: ...and ground the shield layer or two ends of wire tube Be sure to install a No Fuse Breaker NFB between the power supply and the input terminals R S T If using ground fault circuit interrupter please ch...

Страница 20: ...lease change it to a special AC motor for the inverter or add a reactor on the side of the inverter Please lower the carrier frequency if there is longer distance betweent the inerter and the motor Be...

Отзывы: