![Danfoss H1P 045 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/danfoss/h1p-045/h1p-045_service-manual_3672567064.webp)
Charge Pressure Relief Valve Repair
C
Caution
Replace the charge pressure relief valve (V010) as a complete unit. Do not attempt to repair the internal
components of the valve.
P106 040E
V010
V024
22 mm
52 N•m
[38 lbf•ft]
1. Using a 22 mm wrench, remove the charge pressure relief valve (V010).
2. Discard a seal (V024).
3. Inspect the sealing surfaces of the pump for nicks or scratches.
4. Lubricate and install the new seal (V024).
5. Install the charge pressure relief valve, and torque to 52 N•m [38 lbf•ft].
6. Operate vehicle/machine through full range of controls to ensure proper operation.
See
Charge Pressure Relief Valve Adjustment
for adjustment instructions.
Service Manual
H1P 045/053/060/068 Axial Piston Single Pumps
Minor Repair
64 |
©
Danfoss | June 2020
AX152886481964en-000405