Charge Pump Repair
If an auxiliary pump is attached, remove auxiliary pump and coupling before servicing charge pump.
Position pump with front shaft pointing downward. Attach securely to a proper work stand.
If necessary, you must replace charge pump components (gearset, outer ring, valve and pressure balance
plates) as a kit.
Charge pump removal/installation
E101 406E
K500
S100
S300
S200
K200
K150
K400
8 mm
K100
S300
S250
G450
G450
1. Remove end cover/auxiliary pad screws (K400) using a 8 mm internal hex wrench.
Alignment pins (G450) are in the end cover. They may dislodge during disassembly.