EDC Control Repair
Control module and solenoid removal/installation
P106 052E
D025
D1
D025A
D025A
D150
5 mm
13.5 N•m
[10 lbf•ft]
D250
D050 (3X)
D050 (3X)
D084
5 N•m [4 lbf•ft]
4 mm
5 N•m
[4 lbf•ft]
4 mm
F100 (2X)
D300 (2X)
2.5 N•m
[1.8 lbf•ft]
3 mm
1. Using a 5 mm internal hex wrench, remove the six cap screws (D250)
2. Remove the control module and gasket (D150) and discard the gasket.
3. If necessary, remove orifices (F100) using a 3 mm internal hex wrench.
Tag and number the orifices for reinstallation.
4. If screen (D084) is clogged, use a hook to remove retaining ring (D098) and screen.
5. Remove and discard screen (D084).
Service Manual
H1P 045/053/060/068 Axial Piston Single Pumps
Minor Repair
©
Danfoss | June 2020
AX152886481964en-000405 | 47