High Pressure Relief Valve Repair
L150
P106 039E
L068
L060
see table
1. Using a hex wrench wrench shown in the table below, remove the HPRVs (L150).
2. Inspect the sealing surfaces in the pump for nicks or scratches, check the valves for damage.
3. Replace any damaged components.
4. Remove and discard the O-rings (L060) and backup rings (L068).
5. Lubricate and install new backup rings (L068) and O-rings (L060).
6. Install HPRVs, and torque to the value in the table.
Frame size
Wrench size
Torque
069/078/089/100
22 mm
70 N•m [52 lbf•ft]
115/130/147/165/210/250
30 mm
110 N•m [81 lbf•ft]
7. Operate the vehicle/machine through full range of controls to ensure proper operation.
8. Check for leaks.
Service Manual
H1P 045/053/060/068 Axial Piston Single Pumps
Minor Repair
©
Danfoss | June 2020
AX152886481964en-000405 | 63