![Danfoss EC-C1200-450 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/danfoss/ec-c1200-450/ec-c1200-450_user-manual_3449260021.webp)
Figure 5. Overview of the drivetrain system (for reference only).
Cooling
Table 4. Cooling system requirements
Cooling system properties
Speci cation
Cooling type
Liquid cooling
Coolant type
Water or water glycol mixture (glycol max. 50 %)
Coolant temperature
-40º…+65 ºC
-40º…+40 ºC for 350 A version
Coolant ow minimum
10 l/min
Nominal operating pressure
2 bar
Pressure drop
100 mbar with 10 l/min (+25 °C coolant)
See detailed information and speci cations from the product data sheets,
Rated values can be found from the rating plate.
EC-C1200-450
3. Product overview
20 |
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019
| BC265735231757en-000109