Parameter
Meaning
DRIP TRAY
0 = drip tray heater off
1 = drip tray heater on
REV.V. HOT WATER
0 = reversing valve in heating mode
1 = reversing valve in hot water mode
AUX. HEAT 1
0 = stop of internal immersion heater power stage 1
1 = start of internal immersion heater power stage 1
AUX. HEAT 2
0 = stop of internal immersion heater power stage 2
1 = start of internal immersion heater power stage 2
AUX. HEAT 3
0 = stop of internal immersion heater power stage 3
1 = start of internal immersion heater power stage 3
EXT.AUX.HEATER
0 = stop external heat source (230V)
1 = start external heat source (230V)
POT.FREE
0 = potential free output for control of auxiliary heater open
1 = potential free output for control of auxiliary heater closed
CIRC. PUMP DiCi.1
0 = stop circulation pump in discharge circuit 1
1 = start circulation pump in discharge circuit 1
SHUNT DiCi.1
- = closes shunt in discharge circuit 1
0 = shunt unaffected
+ = opens shunt in discharge circuit 1
CIRC. PUMP DiCi.2
0 = stop circulation pump in discharge circuit 2
1 = start circulation pump in discharge circuit 2
SHUNT DiCi.2
- = closes shunt in discharge circuit 2
0 = shunt unaffected
+ = opens shunt in discharge circuit 2
SYSTEM SHUNT
- = closes shunt
0 = shunt unaffected
+ = opens shunt
RET.LINE HP SHUNT
- = closes return line shunt in systems with buffer tank
0 = shunt unaffected
+ = opens shunt in systems with buffer tank
REV. V. POOL
0 = reversing valve in normal mode
1 = reversing valve in pool mode
ALARM
0 = no voltage on output 201.6 External alarm
1 = 230V on output 201.6 External alarm
DIGITAL OUT
0 = no voltage on output 204.1
1 = 5V (2mA) on output 204.1
10.7
INSTALLATION
Parameter
Meaning
HEAT SOURCE
Selecting heat pump type for configuration of control.
Outdoor air with direct evaporation and four-way valve.
POOL
Activates the pool function.
Factory setting:
, range:
– ON
58 – Installation instructions VMGFD102