Caution! A driptray is installed with the purpose of gathering and draining away melt water during
defrosting. Connect a hose or pipe along with a heat trace cable between the outlet of the drip tray and a
drain or a free draining piece of ground. The heat cable must be connected to the terminal provided and
is necessary to prevent ice blockage.
Caution! Check with a spirit level that the heat pump is installed horizontally.
Caution! Incorrect positioning of the heat pump risks reduction of performance.
Caution! The unit with water heater must be placed indoors, in an area with a floor drain.
Caution! The unit with water heater must be placed indoors, on a stable surface. The floor must be able to
support the gross weight of the unit with filled water tank (see Technical data).
Note! Avoid placing the heat pump near windows or walls to noise sensitive areas.
Note! Ensure that there is sufficient distance to neighbouring properties so that they are not exposed to
noise. Applicable local regulations must be followed.
Note! The heat pump should not be enclosed.
Note! Keep the heat pump and its immediate area free of snow, ice, leaves etc.
Note! Remember that the heat pump must have a certain amount of space in order to function and for
servicing. Otherwise there is a risk that the air will recirculate from exhaust to intake. Avoid this by
following the dimensions given below.
Installation instructions VMGFD102 – 11