Menu selection
Meaning
Factory setting
LOG TIME
Time interval between collection points of temperature history in minutes. The history
graphs always show the 60 last collection points, which means that the graphs can dis-
play history from 1 hour up to 60 hours ago.
(The function is not active if there is an active alarm).
1M
(range: 1M / 60M)
BRINE TIME ON
The brine pump starts the set number of seconds before the compressor. Applies at start
of heat pump.
30S
(range: 10S / 90S)
BRINE TIME OFF
The brine pump stops the set number of seconds after the compressor. Applies at stop of
heat pump.
30S
(range: 10S / 60S)
SYSTEM
Menu selection
Meaning
Factory setting
HEAT SOURCE
GROUND OR ROCK
OUTSIDE AIR
(BRINE SOLUTION, DIRECT EVAP.)
B/W
COOLING
PASSIVE COOLING
(
, PASSIVE, INTEGRATED IN HP)
ACTIVE COOLING
(
, PASSIVE/ACTIVE, ACTIVE)
ROOM SENSOR
(
, ON)
POOL
, ON
SHUNT GROUP
, ON
BUFFER TANK (See separate instruction
for buffer tank)
BUFFER TANK
SYSTEM SHUNT
2ND H.C SHUNT
ADDITION
OPTIMUM
(
, CIRC. PUMP, TWO WAY VALVE)
HGW
(
, ON)
FLOW SENSOR
(
, ON)
Permanently ON or ON/
depending on
model.
CURRENT LIMITER
(
, ON)
PHASE FAULT
(
, PHASE READING)
Installation Guide
Domestic heat pumps
Danfoss Heating Solutions
VMGFQ102
47
Содержание DHP-A
Страница 42: ...Menu selection POLSKI E TINA Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 42...
Страница 61: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 61...
Страница 62: ...Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 62...
Страница 63: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 63...