If the sensor cable is connected through a pipe, the pipe must be sealed so that the sensor is not affected by

outgoing air.

1. Position the outdoor sensor on the north or north west side of the house.
2. Connect the sensor to the heat pump’s control system.

6.5

Connect outdoor unit

Caution

The power cable may only be connected to the terminal block intended for this purpose. No other terminal

blocks may be used!

Outdoor unit

Heat pump

 

N/220

211
213

104
218
386
387

125

N/220

126

N/220

127

PE

220/N

211
213
283
104
218
386
387

125

4

5

7

8

1

2

3

6

1

Neutral

2

Fan high speed

3

Fan low speed

4

Motor protection fan

5

Defrost sensor

6

Accessories

7

Heating, drip tray

8

Heating cable

1. Route the power cable through the opening in the top panel of the heat pump to the terminal blocks.
2. Connect the power cable to the terminal block.

6.6

Connect temperature sensor hot water

Sensor for hot water and hot water peak from external water heater is connected in the following way to DHP-L.

311
312
325
326

54

55

54

Hot water sensor

55

Hot water top sensor

Installation Guide

Domestic heat pumps

Danfoss Heating Solutions

VMGFQ102

35

Содержание DHP-A

Страница 1: ...ING MODERN LIVING POSSIBLE Installation Guide Domestic heat pumps DHP A DHP A Opti DHP C Opti DHP C DHP H DHP H Opti DHP H Opti Pro DHP L DHP L Opti DHP L Opti Pro DHP C Opti W W www heating danfoss c...

Страница 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...

Страница 3: ...t 35 6 6 Connect temperature sensor hot water 35 6 7 Selection of system solution and connection of external aux heater 36 7 Menu information 38 8 INFORMATION menu 39 8 1 Sub menu OPERAT 39 8 2 Sub me...

Страница 4: ...s to be taken The symbols are displayed to the left of the text and three different symbols are used to indicate the degree of danger Danger Indicates an immediate danger that leads to fatal or seriou...

Страница 5: ...Hot water top sensor 71 Flow guard 353 Drip tray 362 Shunt valve 406 or 62 Room sensor 408 EVU 417 Defrost sensor 1 2 3 Pipe connections Tap water Heating system Brine system Defrosting tank Expansio...

Страница 6: ...tting 95 C to 85 C Caution The heat pump must be installed by authorised installation engineers and the installation must follow the applicable local rules and regulations as well as these installatio...

Страница 7: ...st only be carried out by a certified engineer Although the heat pump cooling system refrigerant circuit is filled with a chlorine free and environmentally approved refrigerant that will not affect th...

Страница 8: ...thorized electrician and must follow applicable local and national regulations Caution The electrical installation must be carried out using permanently routed cables It must be possible to isolate th...

Страница 9: ...ion pumps can be damaged Caution If the installation is only to be driven by the immersion heater during the installation ensure that the heating system is filled and the brine pump and compressor can...

Страница 10: ...ifted up again it must stand upright for at least an hour before commissioning 3 2 Unpacking 3 2 1 Unpack the heat pump 1 Check that there is no transport damage 2 Remove the packaging 3 2 2 Delivery...

Страница 11: ...is has normally been taken into account during construction and the joists where the heat pump will be located have been reinforced Always check that this has been carried out when installing into a n...

Страница 12: ...ainst the front cover and turn the catch 90 degrees anti clockwise to release the front cover 2 Tilt the front cover outwards 3 Lift the front cover upwards to remove it from the heat pump 3 4 Setting...

Страница 13: ...Disassembled stand Necessary screws nuts and washers 3 4 4 Installation Assemble the stand 1 1 2 3 1 Ends 2 Strut 3 Feet 1 Screw the two horizontal struts together 2 using the two ends 1 as illustrat...

Страница 14: ...rews It may be necessary to push and pull the stand slightly in order to get the screw holes to align 3 Reinstall the side panels Assemble the defrost sensor 1 Slide the mounting for the defroster sen...

Страница 15: ...rews N If the top cover does not align with the side cover plates it may be necessary to drill new 3 mm holes 1 Mark for the new holes 2 Lift off the top cover 3 Drill the holes 3 Install and screw th...

Страница 16: ...e 22 Cu 4 10 kW 28 Cu 12 16 kW 4 Heating system return pipe 22 Cu 4 10 kW 28 Cu 12 16 kW 5 Connection for bleed valve 22 Cu 6 Hot water line 22 mm 7 Cold water line 22 mm 8 Lead in for supply sensor a...

Страница 17: ...ystem return pipe 22 Cu 4 10 kW 28 Cu 12 16 kW 5 Lead in for supply sensor and communication cables 6 Supply line to water heater 22 Cu Only applies to DHP L Opti Pro 7 Return line from water heater 2...

Страница 18: ...6 kW 4 Heating system return pipe 22 Cu 4 10 kW 28 Cu 12 16 kW 5 Lead in for supply sensor and communication cables 6 Return line from water heater to heat pump 22 mm 7 Hot water 22 mm 8 Cold water 22...

Страница 19: ...2 kW 6 Connection for bleed valve 22 Cu 7 Hot water line 22 mm 8 Cold water line 22 mm 9 Expansion outlet brine circuit R25 int 10 Safety valve for temperature and pressure only applies to certain mod...

Страница 20: ...resses in the connecting pipes Caution It is important that the heating system is bled after installation Bleed valves must be installed where necessa ry N Ensure that the pipe installation is carried...

Страница 21: ...ct the factory setting in menu SERVICE AUX HEATER EXTERNAL ADDITION EXTERNAL AUX HEATER 0 Off REV V HOT WATER INT Example system solution 1 System solution for DHP H DHP H Opti DHP H Opti Pro DHP C Op...

Страница 22: ...ve for temperature and pressure only applies to certain models Example system solution 1 System solution for DHP L Opti Pro 118 1 Heat pump 10 Supply line 11 Return line 12 Cold water 13 Hot water 18...

Страница 23: ...control computer also controls an additional shunt located after the external addition For system solution 2 select in menu SERVICE AUX HEATER EXTERNAL ADDITION EXT AUX HEATER ON REV V HOT WATER INT E...

Страница 24: ...ve for temperature and pressure only applies to certain models Example system solution 2 System solution for DHP L Opti Pro 118 1 Heat pump 10 Supply line 11 Return line 12 Cold water 13 Hot water 18...

Страница 25: ...r after the integrated immersion heater The heat pump control computer also controls an additional shunt located after the external addition For system solution 3 select in menu SERVICE AUX HEATER EXT...

Страница 26: ...ly applies to certain models 5 2 4 Connect cold and hot water lines 1 Connect the cold water and hot water pipes with all the necessary components according to the connection diagram for the rele vant...

Страница 27: ...on tank 121 Brine in 122 Brine out A Shut off valve part of 94 B Shut off valve part of 94 C Dirt strainer with shut off valve part of 94 Connection brine DHP C 122 121 80 B C A 94 111 100 80 Shut off...

Страница 28: ...rt of 94 100 Safety valve D Moved out sensor brine out Connection brine DHP C Opti W W 73 71 85 71 Flow guard 73 2 way valve 85 Air bleeding valve 5 3 2 Drill holes for brine pipes Caution Ensure that...

Страница 29: ...at least 1cm every 30 cm Cut them at an angle as illustrated so that rain water cannot get into the pipes 3 Insert the brine pipes 2 into the insert pipes in the installation room 4 Fill in the holes...

Страница 30: ...nsulated 5 3 4 Connect to outdoor unit Connection for the brine circuit from the heat pump to the outdoor unit can be carried out using pipes or hoses Depending on what connection is selected and what...

Страница 31: ...lding construction and the pipe system see Flexible hoses Ensure that pipes at lead ins are not lying against the walls Ensure that the electrical supply cable does not provide a path for vibration be...

Страница 32: ...nected units is 2A 6 1 Electrical components 1 2 3 5 7 6 4 11 12 13 14 10 8 9 15 1 Terminal block applies to the expansion card 2 Terminal block applies to DHP A 3 Defrost card applies to DHP A 4 Term...

Страница 33: ...W immersion heater and shut off compressor 6 Heat pump with 12 kW immersion heater 7 Heat pump with 15 kW immersion heater 8 Fuse phase L1 size 4 has 1 phase compressor 9 Heat pump 6 3 Connecting exte...

Страница 34: ...nnected by a two core cable A maximum cable length of 50 m applies for a cross section of 0 75 mm2 For greater lengths a cross section of 1 5 mm2 is used up to a maximum of 120 m 305 306 50 N For high...

Страница 35: ...387 125 N 220 126 N 220 127 PE 220 N 211 213 283 104 218 386 387 125 4 5 7 8 1 2 3 6 1 Neutral 2 Fan high speed 3 Fan low speed 4 Motor protection fan 5 Defrost sensor 6 Accessories 7 Heating drip tra...

Страница 36: ...normal connection External auxiliary heater I O card output for 3 kW connected and fused with 086U9685 Additional shunt Terminal block 215 216 Internal exchange valve I O card 214 normal connection F...

Страница 37: ...rd 214 kW connected and fused with 086U9685 For DHP A DHP A Opti the electrical connection for system solution 3 must be carried out according to the following table Component Connection Internal imme...

Страница 38: ...emitted when necessary The control system is operated using a keypad and information is shown in a display and by an indicator N The information in the display and menus will vary depending heat pump...

Страница 39: ...ak heating charging anti legionella function with only heat pump opera tion AUX HEAT ER Operation with only auxiliary heater permitted HOT WATER Operation with heat pump for hot water production and a...

Страница 40: ...nsor Pool hysteresis does not affect the integral value 2 C range 1 C 10 C 8 3 Sub menu HEAT CURVE 2 Only appears if shunt group sensor is connected and activated in menu SERVICE INSTALLATION SYSTEM S...

Страница 41: ...IME AUX HEATER 1 AUX HEAT 2 OPERAT TIME AUX HEATER 2 AUX HEAT 3 OPERAT TIME AUX HEATER 3 HOT WATER Operating time for hot water with compressor COOLING Operating time cooling ACT COOLING Operating tim...

Страница 42: ...Menu selection POLSKI E TINA Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 42...

Страница 43: ...ion in days Operat ing mode that permits auxiliary heater must be selected 7D range 1D 90D TOPH TIME Time in hours that the legionella demand is to be fulfilled for legionella operation to be consider...

Страница 44: ...ice Instructions for more information 600 range 50 990 HYSTERESIS If the difference between the actual supply temperature and the calculated supply tem perature is too great see Service Instructions f...

Страница 45: ...STEM SHUNT Only at buffer tank closes shunt 0 shunt unaffected opens shunt HGW SHUNT closes shunt 0 shunt unaffected opens shunt AUX HEAT 1 0 stop aux heater step 1 1 start aux heater step 1 AUX HEAT...

Страница 46: ...s SERVICE TIME 1 activates SERVICE TIME which speeds up the control system s integral calculation and start delay by 60 times FACTORY SET CANCEL starting point no changes made RADIATOR reset factory s...

Страница 47: ...OFF The brine pump stops the set number of seconds after the compressor Applies at stop of heat pump 30S range 10S 60S SYSTEM Menu selection Meaning Factory setting HEAT SOURCE GROUND OR ROCK OUTSIDE...

Страница 48: ...START is set to ON the fans starts and stops at the same time as the compressor and the FAN STOP parameter is inactive 2 C range ON 5 C FAN STOP 3 C FAN STOP The fan stops when the temperature on the...

Страница 49: ...hot water and this value Example 40 3K at a temperature of 43 C in the water heater the shunt switches to the heating system 3K range 1K 10K MAX TEMP Max temperature of the water in the water heater T...

Страница 50: ...g valve on water heater coil 85 10 1 2 Piping installation brine system Expansion bleed vessel with safety valve on the return pipe 100 111 112 Filling device on the return pipe 94 Insulation in the o...

Страница 51: ...ON 3 Set parameter REV V HOT WATER to EXT 10 2 3 Other settings If necessary configure settings for the following see also SERVICE menu and the actual Installation manual COOLING POOL SHUNT GROUP BUF...

Страница 52: ...ore using anti freeze Caution For DHP C Opti W W The pressure on the brine system must not exceed 3 bar and the difference pressure must be at least 120 kPa Bleed the system thoroughly N Anti freeze w...

Страница 53: ...at pump exchanger pipe and outer jacket approximately 47 litres Expansion vessel approximately 3 litres Outdoor unit approximately 7 litres Collector single pipe 28 mm pipe approximately 0 5 litre m 4...

Страница 54: ...afety valve 111 Bleed and expansion tank 112 Expansion vessel 121 Brine in 122 Brine out A Shut off valve part of 94 B Shut off valve part of 94 C Dirt strainer with shut off valve part of 94 D Extern...

Страница 55: ...until fluid clear of air comes out of the return hose from the valve A 14 DHP H DHP L DHP C Opti open the safety valve 100 on bleed and expansion tank 111 and fill it up to 2 3 Close the safety valve...

Страница 56: ...H Opti Pro SP and DHP L Opti Pro SP 1 phase it is imperative that the hot water tem perature changes from default setting 95 C to 85 C Caution When bleeding the circulation pumps water can come into c...

Страница 57: ...ulation pump 2 Check that the circulation pump is running by carrying out the following Listen Place a hand on the pump Listen for air 3 If a constant speed circulation pump does not start perform a m...

Страница 58: ...ting the parameter CIRC PUMP to 0 10 5 7 Testing the auxiliary heating power stages 1 Start the circulation pump by setting the parameter CIRC PUMP to 100 1 if fixed circulation pump 2 Start the first...

Страница 59: ...talled and is ready to be commis sioned to ensure that everything is in order Test operate the heat pump in both heating and hot water modes to ensure that there is no abnormal noise While doing this...

Страница 60: ...ore information 8 If the indoor temperature varies several degrees despite trimming a specific part of the heat curve may need adjusting Check at what outdoor temperature the variation is greatest and...

Страница 61: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 61...

Страница 62: ...Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 62...

Страница 63: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 63...

Страница 64: ...ss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in sp...

Отзывы: