N
If the sensor cable is connected through a pipe, the pipe must be sealed so that the sensor is not affected by
outgoing air.
1. Position the outdoor sensor on the north or north west side of the house.
2. Connect the sensor to the heat pump’s control system.
6.5
Connect outdoor unit
Caution
The power cable may only be connected to the terminal block intended for this purpose. No other terminal
blocks may be used!
Outdoor unit
Heat pump
N/220
211
213
104
218
386
387
125
N/220
126
N/220
127
PE
220/N
211
213
283
104
218
386
387
125
4
5
7
8
1
2
3
6
1
Neutral
2
Fan high speed
3
Fan low speed
4
Motor protection fan
5
Defrost sensor
6
Accessories
7
Heating, drip tray
8
Heating cable
1. Route the power cable through the opening in the top panel of the heat pump to the terminal blocks.
2. Connect the power cable to the terminal block.
6.6
Connect temperature sensor hot water
Sensor for hot water and hot water peak from external water heater is connected in the following way to DHP-L.
311
312
325
326
54
55
54
Hot water sensor
55
Hot water top sensor
Installation Guide
Domestic heat pumps
Danfoss Heating Solutions
VMGFQ102
35
Содержание DHP-A
Страница 42: ...Menu selection POLSKI E TINA Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 42...
Страница 61: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 61...
Страница 62: ...Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 62...
Страница 63: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 63...