Menu selection
Meaning
Factory
setting
2ND H.C SHUNT
Only at buffer tank
- = closes shunt
0 = shunt unaffected
+ = opens shunt
PASSIVE COOLING 0= stop passive cooling
1= start passive cooling
ACT COOLING
0= stop active cooling
1= start active cooling
REV. V. POOL
0 = normal mode for the exchange valve
1 = pool mode for the exchange valve
0-10V
Used for circulation pumps at BUFFER TANK.
TWO WAY VALVE
0 = valve closed, then use a value between 10-100 to open the valve.
9.5
Sub-menu INSTALLATION
Menu selection
Meaning
Factory setting
SYSTEM
N
This menu selection in the SYSTEM menu varies depending
on the selected values.
N
Start in the top menu and work downwards.
Se table below for more information
SERVICE TIME
N
Note! Only used for test operation. The heat pump counts 60
times as fast, which means that the waiting times are elimina-
ted during test operation.
0 = deactivates SERVICE TIME
1 = activates SERVICE TIME, which speeds up the control system’s integral calculation and
start delay by 60 times.
FACTORY SET
CANCEL = starting point, no changes made.
RADIATOR = reset factory settings for radiator system
FLOOR = reset factory settings for under floor heating
RESET OPER. TIME
0 = no reset of operating times
1 = reset of operating times to zero
SENSOR CALIBRA-
TION
OUTDOOR
0, (range: -5°C / 5°C)
SUPPLY LINE
0, (range: -5°C / 5°C)
RETURN LINE
0, (range: -5°C / 5°C)
HOT WATER
0, (range: -5°C / 5°C)
BRINE IN
0, (range: -5°C / 5°C)
BRINE OUT
0, (range: -5°C / 5°C)
DEFR SENSOR
0, (range: -5°C / 5°C)
POOL
0, (range: -5°C / 5°C)
SHUNT GROUP
0, (range: -5°C / 5°C)
HGW TEMPERATURE
0, (range: -5°C / 5°C)
BUFFER TANK
0, (range: -5°C / 5°C)
2ND HEAT CIR.
0, (range: -5°C / 5°C)
SYSTEM SUPPLY
0, (range: -5°C / 5°C)
EXTERNAL FACTOR Affects sensors that are installed inside the heat pump
0 (5°C for DHP-A,
DHP-A Opti)
(range: 0°C / 20°C)
VERSION
Shows the software version which is stored on the display card respectively the I/O-card.
DISPLAY: V X.X
I/O-CARD: V X.X
-
Installation Guide
Domestic heat pumps
VMGFQ102
Danfoss Heating Solutions
46
Содержание DHP-A
Страница 42: ...Menu selection POLSKI E TINA Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 42...
Страница 61: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 61...
Страница 62: ...Installation Guide Domestic heat pumps VMGFQ102 Danfoss Heating Solutions 62...
Страница 63: ...Installation Guide Domestic heat pumps Danfoss Heating Solutions VMGFQ102 63...