DEVIreg™ 132
Installation Guide
7
Note:
A floor sensor enables a more accurate
temperature control and is recommended in
all floor heating applications and
mandatory
under wooden floors to reduce the risk of
over-heating the floor.
•
Place the floor sensor in a conduit in an appropriate
place where it is not exposed to sunlight or draft from
door openings.
•
Equally distant and >2cm from two heating cables.
•
The conduit should be flush with the floor surface -
countersink the conduit if necessary.
•
Route the conduit to the connection box.
•
The bending radius of the conduit must be min
50mm.