DEVIreg™ 132
Installation Guide
11
• Floor manufactures often specify the max tempera-
ture on the top surface of the floor (usually 27-28 °C).
• By default, the maximum floor temperature is set to
35 °C.
• Always use a floor sensor or a room + floor sensor
combination to control floor heating. Without a floor
sensor, the temperature control may be less accurate
and you risk overheating the floor.
Thermal
resist-
ance
[m2K/W]
Examples of
flooring
Details
Approximate
setting for
25 °C floor
temperature
0,05
8 mm HDF
based laminate > 800 kg/m3 28 °C
0,10
14 mm beech
parquet
650 -
800 kg/m3
31 °C
0,13
22 mm solid
oak plank
> 800 kg/m3 32 °C
< 0,17
Max. carpet
thickness suit-
able for floor
heating
acc. to
EN 1307
34 °C
0,18
22 mm solid fir
planks
450 -
650 kg/m3
35 °C