© Danfoss | 2019.02 | 3
VI.GM.A2.02
CCR3+ Controller
105 mm
60 mm
90 mm
122 mm
45 mm
50 mm
36 mm
CCR3+ Controller
MADE
IN POLAND
Retu
rn
Temper
at
ur
e
Co
nt
ro
lle
r
CCR3+
20171213
V3.
12
003Z0396
Supply 24VDC
RoHS
Danf
oss
A
/S
6430 Nordb
or
g,
D
en
m
ar
k
G
S0
B3
B2
B1
G
S4
S3
S2
S1
G
S8
S7
S6
S5
G
S12
S11
S10
S9
G
S16
S15
S14
S13
G
S20
S19
S18
S17
C
O4
O3
O2
O1
V4
V3
V1
V8
V7
V5
V12
V11
V9
V16
V15
V13
V20
V19
V17
C
C
C
C
C
V2
V6
V10
V14
V18
A
B
G
24VDC
TCP/IP
RJ45
POWER
Master
Module
1
Module
2
Module
3
Module
4
Module
5
Module
0
POWER
Maste
r
Module
1
Module
2
Module
3
Module
4
Module
5
Module
0
Lbus
G
G
BO
TO
M
C
V13-16
C
V1-4
C
V5-8
C
V9-12
C
O1-4
0V
24VDC
LBus
RS485
S13-16
G
S1-4
G
S5-8
G
S9-12
G
B1-3 S0
G
TCP/IP
LAN
C
V17-20
S17-20
G
Connector/port
Description
0V
24VDC
0V
– ground (-) power supply
24 VDC(+)
power supply
Lbus
RS485
G
– ground Lbus port (for system expansion)
Lbus
– Lbus port (for system expansion)
G
– ground (Modbus RS 485)
B
– port B (Modbus RS 485)
A
- port A (Modbus RS 485)
C
O1,..,O4
C
– common port dedicated to outputs O1-O4
O1 -
output: Alert Broken Sensor
O2 -
output: Alert Low Temp
O3 -
output: Alert High Temp
O4 -
output: not in use
C
V1-4
C
– common port dedicated to actuators V1-4
V1..V4
– outputs to actuators
C
V5-8
C
– common port dedicated to actuators V5-8
V5..V8
– outputs to actuators
C
V9-12
C
– common port dedicated to actuators V9-12
V9..V12
– outputs to actuators
C
V13-16
C
– common port dedicated to actuators V13-16
V13..V16
– outputs to actuators
Connector/port
Description
C
V17-20
C
– common port dedicated to actuators V17-20
V17..V20
– outputs to actuators
TCP/IP, LAN
TCP/IP
port or IP Modbus port
B1-3, S0
G
B1,B2, B3 defined inputs
S0
– temp. sensor
G
– common ground dedicated to inputs/sensor
S1-4
G
S1..S4
– inputs from sensors
G
– common ground dedicated to sensor S1-4
S5-8
G
S5..S8
– inputs from sensors
G
– common ground dedicated to sensors S5-8
S9-12
G
S9..S12
– inputs from sensors
G
– common ground dedicated to sensors S9-12
S13-16
G
S13..S16
– inputs from sensors
G
– common ground dedicated to sensors S13-16
S17-20
G
S17..S20
– inputs from sensors
G
– common ground dedicated to sensors S17-20
Fig. 3
Wiring scheme - CCR3+ Master Controller