44
180R9270 / IOM APP S 674 - v01 / 03.2013
Instruction
APP S 674 pumps
8
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
4.3 APP S 674 21-38
Pumps size
APP S 674 3.0-3.5
APP S 674 5.1-9.0
APP S 674 21-38
Outlet min. pressure,
continuous
1)
barg
20
30
30
psig
290
435
435
Outlet max. pressure,
MAWP
barg
80
80
80
psig
1,160
1,160
1,160
Inlet operating pressure
2)
barg
0.5-10
2.0-10
2.0-10
psig
7.25-145
29-145
29-145
Inlet design pressure
barg
15
15
15
psig
217
217
217
Min. speed, continuous
rpm
700
700
700
Max. speed, continuous
rpm
3,000
1,800
1,500
Media temperatur
3)
°C
2-50
2-50
2-50
°F
36-122
36-122
36-122
Ambient temperatur
°C
0-50
0-50
0-50
°F
32-122
32-122
32-122
Storage temperature
°C
-40 to +70
-40 to +70
-40 to +70
°F
-40 to +158
-40 to +158
-40 to +158
Weight
Kg
15
40
110
lb
33
88
242
Inlet pressure:
If using lower inlet pressure than stated in above
table, the pump will cavitate, which will damage
the pump.
The inlet line connection must be properly
tightened as entrance of air will cause cavitation.
Outlet pressure:
MAWP (Maximum Allowable Working Pressure)
must be within specifications.
If pump operates below minimum outlet
pressure, it may cause cavitation/erosion in the
pump.
Note: We recommend that the pump unit
includes a pressure gauge at inlet and outlet.
Dry running:
When running, the pump must always be
connected with water supply in order to avoid
pump damage.
Disconnection:
If inlet line is disconnected from the water
supply, the pump will be emptied which will
cause dry running.
When starting up again, follow the bleeding
procedure described in section 4: Initial start-up.
1)
For lower pressure, please contact Danfoss High Pressure Pumps
2)
If inlet pressure exceeds inlet operating pressure, Danfoss recommends inspection of the pump and shaft seal
3)
Dependent on the NaCl concentration
5.
Technical data