42
180R9270 / IOM APP S 674 - v01 / 03.2013
Instruction
APP S 674 pumps
6
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
3.4 Connections
3.4.1 APP S 674 3.0-3.5
3.4.2 APP S 674 5.1-9.0
4 x M8 x 1.25
12 depth
Ø49.82 [1.961
]
Inlet
Outlet
Mounting of flange
connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
Mounting of flange
connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
8 x M8 x 1.25
15 depth
Ø64 [2.52]
Inlet
Outlet