43
180R9270 / IOM APP S 674 - v01 / 03.2013
Instruction
APP S 674 pumps
6
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
3.4 Connections
3.4.1 APP S 674 3.0-3.5
3.4.2 APP S 674 5.1-9.0
4 x M8 x 1.25
12 depth
Ø49.82 [1.961
]
Inlet
Outlet
Mounting of flange
connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
Mounting of flange
connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
8 x M8 x 1.25
15 depth
Ø64 [2.52]
Inlet
Outlet
Instruction
APP S 674 pumps
7
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
3.4.3 APP S 674 21-38
4.
Initial start-up
1.
Flush inlet line before connecting the
pump, to remove possible impurities from
pipes, hoses etc.
2.
Connect pump inlet to inlet line and flush
the pump for 5 min. by using an internal
flushing valve, to remove possible impuri-
ties from pipes, hoses etc.
3.
Loosen top bleeding plug (see item 3.4)
using an Allen key (only plugs with internal
hexagan sockets). Retighten the plug,
when water appears from the bleeding
plug.
4.
Make sure that the direction of rotation of
the electric motor corresponds to the
direction of rotation of the pump (see label
on pump).
5. Now the pump is ready for start-up.
WARNING!
Make sure that the direction of rotation of the
electric motor corresponds to the direction of
rotation of the pump (see label on pump).
Otherwise the pump will be damaged if a
check valve is placed between pump and feed
pump.
4.1 APP S 674 3.0-3.5
4.2 APP S 674 5.1-9.0
8 x M10 x 1.5
17 depth
Ø87 [3.425]
Inlet
Outlet
Internal flushing valve
Internal flushing valve
Mounting of flange
connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
Содержание APP S 674 Series