![Danfoss APP 1.0 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/danfoss/app-1-0/app-1-0_installation-operation-and-maintenance-manual_3517938045.webp)
27
180R9262 / IOM APP 0.6-1.0 Appendices - v02 / 12.2012
Instruction
Recommended service intervals for APP pumps
3.
Appendix 1
Pistons:
The pistons are the heart of the pump regarding
service.
If the pistons break down, the pump will su
ff
er a
breakdown.
In case of doubt - the pistons must be replaced.
The pictures below is ment as a guideline for
evaluating the wear of the sliding surface.
Cavitation of the piston shoes.
New inspection is required in 3,000-4,000 hours.
Cavitation of the piston shoes.
All pistons must be replaced within the next
500-1,000 hours.
Cavitation of the piston shoes.
All pistons must be replaced within the next
100-200 hours.
Cavitation of the piston shoes.
All pistons must be replaced immediately.
Abrasive wear of the piston shoes.
All pistons must be replaced immediately.